3031
1
DEF-Tank temperature: below minimum
3031
3
Sensor error urea tank temperature; short circuit to battery
3031
4
Sensor error urea tank temperature; short circuit to ground
97
12
Water in fuel level pre
fi
lter; maximum value exceeded
523946
0
Zerofuel calibration injector 1 (in
fi
ring order); maximum value exceeded
523947
0
Zerofuel calibration injector 2 (in
fi
ring order); maximum value exceeded
523948
0
Zerofuel calibration injector 3 (in
fi
ring order); maximum value exceeded
523949
0
Zerofuel calibration injector 4 (in
fi
ring order); maximum value exceeded
523950
0
Zerofuel calibration injector 5 (in
fi
ring order); maximum value exceeded
523951
0
Zerofuel calibration injector 6 (in
fi
ring order); maximum value exceeded
523946
1
Zerofuel calibration injector 1 (in
fi
ring order); minimum value exceeded
523947
1
Zerofuel calibration injector 2 (in
fi
ring order); minimum value exceeded
523948
1
Zerofuel calibration injector 3 (in
fi
ring order); minimum value exceeded
523949
1
Zerofuel calibration injector 4 (in
fi
ring order); minimum value exceeded
523950
1
Zerofuel calibration injector 5 (in
fi
ring order); minimum value exceeded
523951
1
Zerofuel calibration injector 6 (in
fi
ring order); minimum value exceeded
523612
12
Internal software error ECU
175
2
Customer oiltemperature: signal unplausible
523973
14
SCR Tamper detection; derating timer below limit 1
523974
14
SCR Tamper detection; derating timer below limit 2
523975
14
Urea quality; derating timer below limit 1
523976
14
Urea qulaity; derating timer below limit 2
523977
14
Urea tank level; derating timer below limit 1
523978
14
Urea tank level; derating timer below limit 2
168
0
Physikal range check high for battery voltage
168
1
Physikal range check low for battery voltage
172
0
Physical range check high for intake air temperature
172
1
Physical range check low for intake air temperature
523980
14
Bad quality of reduction agent detected
523922
12
Over temperature error on burner shut of valve
1180
0
Physical range check high for exhaust gas temperature upstream turbine
1180
1
Physical range check low for exhaust gas temperature upstream turbine
523914
5
Glow plug control release line; short circuit error
523914
11
Glow plug control; internal error
524018
14
DPF wasn´t regenerated, power reduction phase 1 (manuell regeneration request)
524022
14
DPF wasn´t regenerated, power reduction phase 2 (manuell regeneration request)