September 2016
Part No.1272857
GTH-1544
4-7
Section 4 • Fault Codes
FAULT CODES
523602
0
High fan speed; warning threshold exceeded
523602
0
High fan speed; shut off threshold exceeded
97
3
Sensor error water in fuel; signal range check high
97
4
Sensor error water in fuel; signal range check low
94
3
Sensor error low fuel pressure; signal range check high
94
4
Sensor error low fuel pressure; signal range check low
94
1
Low fuel pressure; warning threshold exceeded
94
1
Low fuel pressure; shut off threshold exceeded
174
0
High low fuel temperature; warning threshold exceeded
174
0
High Low fuel temperature; shut off threshold exceeded
523619
2
Physical range check high for exhaust gas temperature upstrem (SCR-CAT)
523915
0
HCI dosing valve (DV1); overcurrent at the end of the injection phase
523915
12
HCI dosing valve (DV1); powerstage over temperature
523915
3
HCI dosing valve (DV1); short circuit to battery
523915
3
HCI dosing valve (DV1); short circuit to battery high side
523915
4
HCI dosing valve (DV1); short circuit to ground
523915
11
HCI dosing valve (DV1); short circuit high side powerstage
523916
2
Sensor HCI dosing valve (DV1) downstream pressure; plausibility error
523916
0
Physical range check high for HCI dosing valve (DV1) downstream pressure; shut off
regeneration
523916
1
Physical range check low for HCI dosing valve (DV1) downstream pressure; shut off regeneration
523916
3
Sensor error HCI dosing valve (DV1) downstream pressure; signal range check high
523916
4
Sensor error HCI dosing valve (DV1) downstream pressure; signal range check low
523917
2
Sensor DV1 & DV2 upstream pressure; plausibility error
523917
0
Physical range check high for DV1 & DV2 upstream pressure; shut off regeneration
523917
1
Physical range check low for DV1 & DV2 upstream pressure; shut off regeneration
523917
3
Sensor error DV1 & DV2 upstream pressure; signal range check high
523917
4
Sensor error DV1 & DV2 upstream pressure; signal range check low
523918
2
Sensor DV1 & DV2 upstream temperature; plausibility error
523918
0
Physical range check high for DV1 & DV2 upstream temperature; shut off regeneration
523918
1
Physical range check low for DV1 & DV2 upstream temperature; shut off regeneration
523918
3
Sensor error DV1 & DV2 upstream temperature; signal range check high
523918
4
Sensor error DV1 & DV2 upstream temperature; signal range check low
676
11
Cold start aid relay error.
676
11
Cold start aid relay open load
729
5
Cold start aid relay open load