Service and Repair Manual
November 2016
Ground Controls
36
GS-2669 DC • GS-3369 DC • GS-4069 DC
Part No. 1272220GT
2
Locate the level sensor in the ground controls
compartment.
1 ground control box
2 level sensor
3
Tag and disconnect the level sensor wire
harness from the chassis wire harness.
4
Remove the level sensor retaining fasteners
and remove the level sensor from the
machine.
5
Install the new level sensor onto the machine
with the "X" on the level sensor base towards
the steer end of the machine. Install and
tighten the level sensor retaining fasteners.
Tip-over hazard. The tilt level
sensor must be installed with the
"X" on the level sensor base
towards the steer end of the
machine. Failure to install the tilt
level sensor as instructed could
result in the machine tipping over
causing death or serious injury.
1 "Y" indicator
2 level sensor
3 "X" indicator
4 chassis
6
Connect the wire harness to the level sensor.
7
Adjust the level sensor retaining fasteners
until the bubble in the top of the level sensor is
centered in the circles.
Note: Be sure there are threads showing through
the top of the adjusting fasteners.
8
Turn the key switch to ground control and pull
out the red Emergency Stop button to the on
position at both ground and platform controls.
Result: The tilt sensor alarm should not sound.