8
Genie AWP
Part No. 33424
Operator’s Manual
Fourth Edition
Pre-operation Inspection & Function Tests
Observe and Obey:
Conduct a thorough pre-operation inspection
and function test before each work shift.
Immediately tag and remove from service a
damaged or malfunctioning machine.
Repair any machine damage or malfunctions
before operating machine.
Pre-operation Inspection
Be sure that all decals are legible and in place.
Be sure that the operator’s manual is legible and
in the storage container located in the platform.
Check for damage and improperly installed or
missing parts:
·
Electrical components, wiring and
electrical cables
·
Hydraulic power unit, hoses, fittings and
cylinder
·
Platform entry mid-rail
·
Sequencing cables and pulleys
·
Lifting chains and idler wheels
·
Nuts, bolts and other fasteners
·
Weld or structural cracks
·
Mast columns and counterweight
·
Breather cap
·
Outriggers, leveling jacks and footpads
Perform quarterly and annual machine
inspections. Keep records for three years.
See the Genie AWP service manual for details.
Breather Cap
Component damage will occur if the machine
is operated without a breather cap.
The first time this
machine is set up for
use, the pipe plug in the
hydraulic reservoir
should be removed and
permanently replaced
with a breather cap.
A breather cap is supplied and can be found
in an envelope taped to the mast near the
platform controls.