Part No. 43063
Genie Z-30/20
4 - 13
Service Manual - Third Edition
Section 4 - Scheduled Maintenance Procedures
TABLE
B
PROCEDURES
2 Turn the key switch to platform control and lift
the red Emergency Stop switch cover and
move the toggle switch to the
ON
position at the
ground controls. Pull out the Emergency Stop
Button to the
ON
position at the platform
controls.
3 Lower the boom into the stowed position.
4 Choose a point on the machine; i.e., contact
patch of a tire, as a visual reference for use
when crossing the start and finish lines.
5 Bring the machine to maximum drive speed
before reaching the start line. Begin timing
when your reference point on the machine
crosses the start line.
6 Continue at full speed and note the time when
the machine reference point passes over the
finish line.
Drive speed: stowed position
35:1 torque hubs
40 ft/6.1 sec
12.2 m/6.1 sec
49:1 torque hubs
40 ft/8.6 sec
12.2 m/8.6 sec
B-14
Test the Alarm Package
- Optional Equipment
The alarm package includes:
· Travel alarm
· Descent alarm
· Flashing beacon
Alarms and a beacon are installed to alert
operators and ground personnel of machine
proximity and motion. The alarm package is
installed on the function manifold side turntable
cover.
1 Turn the key switch to ground control and lift
the red Emergency Stop switch cover and
move the toggle switch to the
ON
position at the
ground controls.
Result: The flashing beacon should be on and
flashing.
2 Activate the function enable switch and move
the primary boom switch to the
DOWN
position,
hold for a moment and then release it. Move
the secondary boom switch to the
DOWN
position, hold for a moment and then release it.
Result: The descent alarm should sound when
each switch is held down.
3 Turn the key switch to platform control.
4 At the platform controls pull out the Emergency
Stop button to the
ON
position.
Result: The flashing beacon should be on
and flashing.
5 Press down the foot switch. Move the primary
boom switch to the
DOWN
position, hold for a
moment and then release it. Move the
secondary boom switch to the
DOWN
position,
hold for a moment and then release it.
Result: The descent alarm should sound when
each control switch is held down.