genesis
32-Output Controller - Technical Manual
Page 8 V4, O/C Manual – Nov 2005
Open Collector Connection:
+12V
DC
OUT
1
OUT
2
OUT
3
OUT
4
OUT
5
OUT
6
OUT
7
OUT
8
OV
DC
NOTE:
Outputs
9-16, 17-24 and 25-32 all use the above format.
0v
32 31 30 29 28 27 26 25
+12v 0v
24 23 22 21 20 19 18 17
+12v
0v
16 15 14 13 12 11 10 9
+12V 0v
8 7 6 5 4 3 2 1
+12V
Each open collector output switches to ground (-ve) when triggered,
and is capable of sinking up to 100 mA, 12v DC.
genesis
32-Output Controller - Technical Manual
Page 9 V4, O/C Manual– Nov 2005
Mounting:
The 32 Output Open Collector Module is designed to mount within the
HDW-001, metal equipment cabinet. Using this cabinet, it is possible
to mount the GEN-050 OC Module, along with up to 4 x GEN-060
Relay Output Modules within the one cabinet, or any other combina-
tion of Genesis equipment may also be mounted with 32 Output Open
Collector Module.
The four screws supplied with the 32 Output Open Collector
Module are for securing the controller to the stand-offs on the
HD-001.
Avoid installing the 32 Output Open Collector Module outdoors.