                                                                             32-Output Controller - Technical Manual

 

Page 6                                                                         V4, O/C Manual – Nov 2005 

12v DC POWER INPUT 

TERMINALS 

 Supplied for connection of 

12v DC to power the module.  

Genesis recommends only 

using factory recommended 

power supplies with Genesis 

devices. 

RESET BUTTON 

Used when generating 

a hardware reset to 

the device processor.  

Use only under in-

struction from your 

TAMPER INPUT: 

Provided to allow 

normally closed 

connection of a 

cabinet tamper to 

this device. 

SERIAL NUMBER 

Each Genesis device is 

fitted with it’s own unique 

Serial Number.  This num-

ber will need to be entered 

into the Genesis Master 

Unit, via the technician 

software, before the device 

will come on line. 

Removal of the Serial Num-

ber will void Warranty 

ALIVE and RX  LED’s 

Provides a quick indication as to system status. 
Flashing ALIVE LED = Device Processor OK. 

Flashing RX LED = LAN Comms OK 

PROGRAMMING HEADER 

The programming header is supplied to allow 

easy 

flash

 upgrading for any future features. 

Please contact your distributor for  more de-

O/C Module Layout: 

genesis 

 

                                                                           32-Output Controller - Technical Manual

 

Page 11                                                                          V4, O/C Manual– Nov  2005 

The Master Unit 

must

 always be the first  de-

vice on the LAN.  This device is factory fitted 
with a 

180

 LAN Termination Resistor. 

The shield from the LAN cable should run the 
length of the LAN, and should be connected to 

communications earth

, at the 

Master Unit

 

only

 

The shield terminals on each device are for 
connection of shield cables, and do not con-
nect to the device proper in any way 
 
Up to 127 additional Genesis devices in total 
can be connected to the Genesis LAN, across 
a total LAN length of 

up to

 1500 meters.  

 
The 

last

 device on the Genesis LAN 

must

 be 

fitted with its termination link.  This link fits a 

180

 resistor to the last device on the LAN. 

 

No other devices should have a termination 
link fitted

.  If connected as described above, 

the LAN should have an impedance of approxi-
mately 

90

, plus the resistance of the LAN 

cable. *

Don’t test  LAN impedance with any devices powered up. 

 

Ensure the cable shield is 

not

 connected to 

any ground or to any voltage on any device 
and that the cable shield is only connected to a 
communications earth at the Master . 

Genesis LAN (cont.):

 

    

 

  

Correct LAN configuration   

 

Correct LAN Configuration

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Master Unit 

 
 

GEN001

 

Remote 

Access 
Station 

 

GEN030

 

Expander 

Unit 

 

GEN010

 

Two Door 
Controller 

 

GEN045

 

A

Connect to Communications Earth 

B

A

SHD

B

A

SHD

B

A

SHD

B

SHD

Summary of Contents for GEN-050

Page 1: ...tion industry As such knowledge of these industries on the part of the installer is assumed Genesis takes no responsibility for any damage financial loss or injury caused to any equipment property or...

Page 2: ...ents TABLE OF CONTENTS 2 PARTS CHECKLIST 3 SPECIFICATIONS 4 FEATURES AND BENEFITS 5 OC MODULE LAYOUT 6 7 OPEN COLLECTOR CONNECTION 8 MOUNTING 9 GENESIS LAN 10 11 POINTS TO NOTE 12 OUTPUT LOCATION CAHA...

Page 3: ...17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 Device Output Information genesis 32 Output Controller Technical Manual Page 3 V4 O C Manual Nov 2005 Parts Checklist 1 x 32 Output Open Collector Modu...

Page 4: ...Controller Technical Manual Page 13 V4 O C Manual Nov 2005 System Layout O C 32 Output Controllers for Automation Lift Control Door Con trol up to 512 Outputs Up to 127 LAN Device modules on RS485 2 w...

Page 5: ...up to 300mA in current Low voltage alarms may be generated if the devices draw more current than the power supply is capable of supplying genesis 32 Output Controller Technical Manual Page 5 V4 O C M...

Page 6: ...005 The Master Unit must always be the first de vice on the LAN This device is factory fitted with a 180 LAN Termination Resistor The shield from the LAN cable should run the length of the LAN and sho...

Page 7: ...evices may appear on line while others are off line The Genesis LAN is an industry standard multi drop RS 485 configuration Do Not Tee Off or Star configure your LAN For STAR configuration please refe...

Page 8: ...100 mA 12v DC genesis 32 Output Controller Technical Manual Page 9 V4 O C Manual Nov 2005 Mounting The 32 Output Open Collector Module is designed to mount within the HDW 001 metal equipment cabinet U...

Reviews: