genesis
32-Output Controller - Technical Manual
Page 6 V4, O/C Manual – Nov 2005
12v DC POWER INPUT
TERMINALS
Supplied for connection of
12v DC to power the module.
Genesis recommends only
using factory recommended
power supplies with Genesis
devices.
RESET BUTTON
Used when generating
a hardware reset to
the device processor.
Use only under in-
struction from your
TAMPER INPUT:
Provided to allow
normally closed
connection of a
cabinet tamper to
this device.
SERIAL NUMBER
Each Genesis device is
fitted with it’s own unique
Serial Number. This num-
ber will need to be entered
into the Genesis Master
Unit, via the technician
software, before the device
will come on line.
Removal of the Serial Num-
ber will void Warranty
ALIVE and RX LED’s
Provides a quick indication as to system status.
Flashing ALIVE LED = Device Processor OK.
Flashing RX LED = LAN Comms OK
PROGRAMMING HEADER
The programming header is supplied to allow
easy
flash
upgrading for any future features.
Please contact your distributor for more de-
O/C Module Layout:
genesis
32-Output Controller - Technical Manual
Page 11 V4, O/C Manual– Nov 2005
The Master Unit
must
always be the first de-
vice on the LAN. This device is factory fitted
with a
180
Ω
LAN Termination Resistor.
The shield from the LAN cable should run the
length of the LAN, and should be connected to
a
communications earth
, at the
Master Unit
only
.
The shield terminals on each device are for
connection of shield cables, and do not con-
nect to the device proper in any way
Up to 127 additional Genesis devices in total
can be connected to the Genesis LAN, across
a total LAN length of
up to
1500 meters.
The
last
device on the Genesis LAN
must
be
fitted with its termination link. This link fits a
180
Ω
resistor to the last device on the LAN.
No other devices should have a termination
link fitted
. If connected as described above,
the LAN should have an impedance of approxi-
mately
90
Ω
, plus the resistance of the LAN
cable. *
Don’t test LAN impedance with any devices powered up.
Ensure the cable shield is
not
connected to
any ground or to any voltage on any device
and that the cable shield is only connected to a
communications earth at the Master .
Genesis LAN (cont.):
Correct LAN configuration
Correct LAN Configuration
Master Unit
GEN001
Remote
Access
Station
GEN030
Expander
Unit
GEN010
Two Door
Controller
GEN045
A
Connect to Communications Earth
B
A
SHD
B
A
SHD
B
A
SHD
B
SHD