General AOH13PNCC Operating Manual Download Page 15

En-14

Make sure the dust collection unit is properly mounted before cleaning or performing other tasks
on it. If the unit is not properly mounted, it could fall off and cause damage or injury.

The display section for the clean air indicator will flash when it is time for the periodic cleaning of the dust collection unit.

• When the flashing of the display section for the clean air indicator is slow (approximately 1 flash every 4 seconds)

This will flash after approximately 400 hours of operation. Cleaning of the dust collection unit as soon as possible is
recommended.

When the flashing of the display section for the clean air indicator is fast (approximately 1 flash every 2 seconds)

This will flash after approximately 500 hours of operation. Stop the air cleaning operation and clean the dust collection
unit.

As a guideline, clean every 6 months.

If unusual sounds (like the rushing of air or popping) are heard, clean the dust collection unit as quickly as possible.

If the air cleaning check function is operating, open the intake grille and press the MANUAL AUTO button.

CLEANING THE PLASMA AIR CLEANING FILTER

 CAUTION!

Removing the dust collection unit

1. Use the remote controller to stop opera-

tion and unplug the power cord.

2. Open the intake grill and remove the right-

side air filter. (Refer to page 13.)

3. Remove the dust collection unit.

(Note that the figure below shows the unit without the
grille. This is for explanatory purposes only. The actual
intake grille cannot be removed.)

Grasp  the  handle  of  the  dust  collection  unit.  Pull  up
(shown as direction 

1

) and then pull down (shown as

direction 

2

) to remove.

Handle

Cleaning the dust collection unit

Wash with water and dry.

1

Soak the dust collection unit in warm water (40 to 45

°

C) for 10 to 15 minutes. If the dust collection unit is

extremely dirty, extremely dilute a mild synthetic laun-
dry detergent (low or neutral alkalinity) to 15 times
the standard concentration and allow the dust collec-
tion unit to soak in it.

2

Gently move up and down and to the right and left. A
soft  sponge  can  also  be  used  to  wipe  the  rear  sur-
face.

3

Rinse with clean water.

4

Shake the dust collection unit to drain off the water.
(If the dust collection unit is extremely dirty, repeat
Steps 

1

 through 

4

 two or three more times.)

5

Place the dust collection unit in the shade and allow
it to dry completely.

Only  use  a  mild  synthetic  laundry  detergent  (low  or
neutral alkalinity).

Never disassemble the dust collection unit.

Never soak the dust collection unit in hot water.

Never wipe the dust collection unit with a scrub brush
or other hard or abrasive items.

Never insert a brush into the inside of dust collection
unit for washing. This will damage the thin fibers in-
side and cause malfunctioning of the air cleaning unit.

Never use dryer or other device to blow hot air on the
dust  collection  unit.  This  will  cause  deformation  or
other damage.

Все каталоги и инструкции здесь:

 http

:

//splitoff.ru/tehn-doc.html

Summary of Contents for AOH13PNCC

Page 1: ...as normas seguintes By conformance with the standards the referenced products follows the provisions of the directives listed below In Übereinstimmung mit den Standards erfüllen die obengenannten Produkte den Verordnungen der unten aufgeführten EG Richtlinien Par leur conformité aux normes précitées les appareils de ce type répondent aux exigences des directives suivantes De acuerdo con estas norm...

Page 2: ...UTION En 1 ROOM TEMP CLEAN AIR POLLUTED AIR OPERATION TIMER SWING AIR CLEAN INDICATOR HI POWER 1 2 34 5 6 7 8 9 0 A B C D E F H I J G PRESSIONE MASSIMA ASPIRAZIONE 800 kPa EMISSIONE 2 700 kPa REFRIGERANTE R22 1 050 g DIMENSIONI E PESO APPARECCHIO INTERNO Altezza Larghezza Profondità 290 815 215 mm Peso 11 5 kg netti APPARECCHIO ESTERNO Altezza Larghezza Profondità 535 695 250 mm Peso 35 kg netti Μ...

Page 3: ...lly to maintain the set temperature and the tem perature is kept constant at all times SLEEP TIMER When the SLEEP timer button is pressed during heating mode the air conditioner s thermostat setting is gradually lowered during the period of operation during cooling mode the thermostat setting is gradually raised during the period of operation When the set time is reached the unit auto matically tu...

Page 4: ...function to op erate incorrectly If this button is pressed during normal op eration the unit will switch to test opera tion mode and the Indoor Unit s OPERA TION Indicator Lamp and TIMER Indicator Lamp will begin to flash simultaneously To stop the test operation mode either press the TEST RUN button once again or press the START STOP button to stop the air conditioner Remote Control Unit Display ...

Page 5: ...e side to open it Slide in the direction of the arrow while pressing the mark 2 Insert batteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current Time 1 Press the TIME ADJUST button Fig 6 Z Use the tip of a ball point pen or other small object to press the button 2 Use the SET TEMP SET TIME buttons Fig 5 Q to adjust the clock to the current time...

Page 6: ...re To Set the Fan Speed Press the FAN CONTROL button Fig 5 T Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About three seconds later the entire display will reappear When set to AUTO Heating Fan operates so as to optimally circulate warmed air However the fan will operate at very low speed when the temperature of the air issued from the indoor...

Page 7: ...ng Use to warm your room When Heating mode is selected the air conditioner will operate at very low fan speed for about 3 to 5 minutes after which it will switch to the selected fan setting This period of time is provided to allow the indoor unit to warm up before begin full operation When the room temperature is very low frost may form on the outside unit and its performance may be reduced In ord...

Page 8: ...the operation of the remote controller The clean air indicator does not respond to some contaminants Response by clean air indicator Tobacco smoke incense aerosol sprays insect sprays cosmetic sprays alcohol beverages cooking etc water vapor from kitchen or bathroom and others No response by clean air indicator Dust pollen mold spores mite particles and others Air cleaning During operation the uni...

Page 9: ...t To operate Hi power 1 Start the operation in any one of the following AUTO COOL HEAT DRY or FAN Refer to pages 5 and 6 for information about starting these operations 2 Press the HI POWER button Fig 5 X The indicator lamp for hi power red will light up To stop Hi power Press the HI POWER button The indicator lamp for hi power red will go out The unit will return to normal operation Hi power oper...

Page 10: ...oor unit sTIMER Indicator Lamp green Fig 3 8 will light 3 Use the SET TEMP SET TIME button Fig 5 Q to ad just the desired OFF time or ON time Set the time while the time display is flashing the flashing will continue for about five seconds button Press to advance the time button Press to reverse the time About five seconds later the entire display will reappear To Use the Program timer 1 Press the...

Page 11: ...T STOP button About the SLEEP Timer To prevent excessive warming or cooling during sleep the SLEEP timer function automatically modifies the thermostat setting in accordance with the set time setting When the set time has elapsed the air conditioner completely stops During Cooling Dry operation When the SLEEP timer is set the thermostat setting is auto matically raised 1 C every sixty minutes When...

Page 12: ...in a room with infants chil dren elderly or sick persons the air direction and room temperature should be considered carefully when making settings Vertical Air Direction Adjustment Press the AIR FLOW DIRECTION button Fig 5 V Each time the button is pressed the air direction range will change as follows 1 2 3 4 5 6 7 Types of Air flow Direction Setting 1 2 3 During Cooling Dry modes 3 4 5 6 7 Duri...

Page 13: ...en the air conditioner is operated with the controls on the Main Unit it will operate under the same mode as the AUTO CHANGEOVER mode se lected on the Remote Control Unit see page 6 During MANUAL AUTO operation the thermostat is automatically set at a standard temperature setting 24 C The fan speed selected will be AUTO and the airflow direction will be the standard direction cooling 1 heat ing 6 ...

Page 14: ...ower tabs are returned properly to their holes in the panel 4 Close the Intake Grille Press on the four locations at the bottom of the grille to securely close the intake grille If the intake grille is not closed securely the temperature monitor will display a and the operation of the air cleaning unit will be stopped Dust can be cleaned from the Air Filter either with a vacuum cleaner or by washi...

Page 15: ...w shows the unit without the grille This is for explanatory purposes only The actual intake grille cannot be removed Grasp the handle of the dust collection unit Pull up shown as direction 1 and then pull down shown as direction 2 to remove Handle Cleaning the dust collection unit Wash with water and dry 1 Soak the dust collection unit in warm water 40 to 45 C for 10 to 15 minutes If the dust coll...

Page 16: ...in the frame If the dust collection unit is not properly mounted the red operation lamp and green timer lamp will flash a will be displayed in the temperature monitor and the air cleaning opera tion will stop CLEANING THE PLASMA AIR CLEANING FILTER 2 Mount the air filter and close the intake grille Refer to page 13 After cleaning the dust collection unit if the red oper ating lamp and green timer ...

Page 17: ...at a time Back of air filter Light regenerated deodorizing filter frame Top tabs Cleaning the light regenerated deodor izing filter 1 Dry the light regenerated deodorizing fil ter in direct sunlight Dry the light regenerated deodorizing filter in direct sunlight It is recommended that this filter be left in direct sun light for 6 hours Never wash the filter with water or other liquid Light regener...

Page 18: ...temperature changes During Heating operation a sizzling sound may be heard occasional This sound is produced by the Automatic Defrosting operation Some smell may be emitted from the indoor unit This smell is the result of room smells furniture tobacco etc which have been taken into the air conditioner The operation of the air cleaning unit produces a small amount of ozone which can be smelled Duri...

Page 19: ... This lamp will flash slowly after approximately 400 hours of op eration of the clean air indicator Stop the operation unplug the power cord and clean the dust collection unit and deodorizing filter This lamp will flash rapidly after approximately 500 hours of op eration of the clean air indicator The air cleaning operation will be stopped when this flashing occurs Make sure the operation is stopp...

Page 20: ...If the intake grille is opened during operation a safety device will stop the operation of the air cleaning unit Use the remote con troller to stop the operation close the grille and then restart the operation Is the dust collection unit wet For safety reasons the safety device will stop the air cleaning operation if the dust collection unit is wet Use the remote con troller to stop the operation ...

Page 21: ...age 3 Use of other electrical appliances electric shaver etc or nearby use of a wireless radio transmitter may cause the air conditioner to malfunction In this event temporarily disconnect the Power Supply Plug reconnect it and then use the Remote Control Unit to resume operation Heating Performance This air conditioner operates on the heat pump principle absorbing heat from outdoor air and transf...

Reviews: