background image

10

Install the bag hanger 

E

 onto the drum as shown in 

F

.

STEP 5 - ATTACH THE BAG HANGER TO THE DRUM 

– MODEL 10-105 M1 only

Use a belt clamp to attach the collector bag to the 

lower portion of the drum. 

Note: Before tightening the clamp make sure the metal 

strap is sitting in the groove on the lower portion of the 

drum to create an airtight seal between the drum and the 

bag.

STEP 9 - INSTALL THE COLLECTOR BAG ON THE DRUM

E

F

If you have model 10-105CF M1 (with canister filter) skip 

ahead to step #11.

Slip the second belt clamp through the opening in 

the filter bag until it comes out through the hole at the 

other end 

I

, then use

 

the belt clamp to attach the filter 

bag to the upper portion of the drum 

J

Note: Before tightening the clamp make sure the metal 

strap is sitting in the groove on the upper portion of the 

drum to create an airtight seal between the drum and the 

bag.

STEP 7 - ATTACH THE HOSE INLET

Fit the hose inlet (“Y” fitting) on the fan/motor assembly 

as shown and secure it in place with the supplied phil-

lips head screw.

G

STEP 6 - ATTACH THE GASKET AND DUST OUTLET TO FAN/

MOTOR ASSEMBLY

Place the gasket on top of the fan/motor assembly, 

G

then place the dust outlet on the gasket and secure in 

place using 8 bolts, 

H

.

Note: Do not overtighten the bolts or the threaded holes 

in the base will strip and/or the gasket will squeeze out 

and the outlet will crack.

H

Using the supplied hose clamps 

G

, attach one end of 

the hose to the drum and the other end to the inlet on 

the fan/motor assembly as shown in 

H

.

STEP 8 - ATTACH THE HOSE TO FAN/MOTOR ASSEMBLY& DRUM

H

STEP 10 -INSTALL THE FILTER BAG ON THE DRUM 

- #10-105 M1 only

I

J

G

Summary of Contents for 10-105 M

Page 1: ...ty rods Equipped with 2 micron filter bag Not included on CF canister filter model Quick release bag clamps with metal straps Intake screen prevents larger pieces from jamming in the impeller SPECIFIC...

Page 2: ...p this manual handy for future reference Disclaimer The information and specifications in this manual pertain to the unit as it was supplied from the factory at the time of printing Because we are com...

Page 3: ...dard 2 year Limited Warranty or under our Limited Lifetime Warranty all defective parts components or machinery must be returned freight or postage prepaid to General International or to a nearby dist...

Page 4: ...r with the power on 14 To avoid health hazards from vapors or dusts do not vacuum toxic material 15 Do not insert hands or fingers or any foreign objects into ventilation inlet and outlet openings 16...

Page 5: ...nding reduces the risk of electric shock The motor of this machine is wired for 110V single phase operation and is equipped with a 3 conductor cord and a 3 prong grounding plug A to fit a grounded typ...

Page 6: ...MAIN PARTS AND COMPONENTS A HOSE B DRUM C FAN MOTOR ASSEMBLY D BASE E VERTICAL SUPPORT RODS F HOSE INLET Y FITTING G FILTER BAG 10 105 M1 ONLY H CANISTER FILTER 10 105CF M1 ONLY I COLLECTOR BAG J BELT...

Page 7: ...of this machine is rated at ap proximately 80 to 85 db during operation Make sure that adequate hearing protection is used and that the overall sound level within the working environment is taken into...

Page 8: ...r in your shop The dust collector is equipped with a 6 main hose inlet that is fitted with a dual inlet Y fitting allowing you to connect up to two 4 dust hoses LAYING OUT A PLAN FOR THE PIPING For pe...

Page 9: ...needed at this time The fan motor assembly is heavy do not overexert Turn the base back over right side up and place the fan motor assembly on the plate Line up the mounting holes and attach the assem...

Page 10: ...ghtening the clamp make sure the metal strap is sitting in the groove on the upper portion of the drum to create an airtight seal between the drum and the bag STEP 7 ATTACH THE HOSE INLET Fit the hose...

Page 11: ...ARING PROTECTION IS USED AND THAT THE OVERALL SOUND LEVEL WITHIN THE WORKING ENVIRONMENT IS TAKEN INTO CONSIDERATION Basic assembly is now complete and your dust col lector is ready to be put into ser...

Page 12: ...e of the unit clean and wipe off excessive dust or dirt with a dry rag Clean filters bags on 10 105 or canisters 10 105CF on a regular basis and replace as needed Periodically inspect inside of all pi...

Page 13: ...he canister filter may become clogged and affect air flow as well the overall efficiency of the unit Should you notice a drop in the efficiency or performance of the unit it may be a sign that it is t...

Page 14: ...products please visit our website at www general ca 1 Micron Canister Filter 10 106C Clear Plastic Collector Bag 10 120 Window Type Collector Bag 10 125 2 Micron Filter Bag 10 115 Dust Collector Acce...

Page 15: ...15 Not supplied required for model 10 105CF M1 15...

Page 16: ...19 WASHER 5 16 4 10105 20 HOSE CLAMP 5 2 10105 21 HOSE 5 1 10105 22 DRUM 1 10105 23 COLLECTOR BAG ITEM 10 120 3 10105 24 FILTER 1 10105 25 BELT CLAMP 2 10105 26 SUPPORT ROD 2 10105 27 BAG HANGER 1 10...

Page 17: ...CAP 3 4 1 10106C 31 CANISTER FIXING PLATE 2 10106C 32 BEARING 1206 2 10106C 35 FLAPPER 3 10106C 36 SPINDLE 1 PART DESCRIPTION SPEC QTY 10106C 38 ROUND HEAD SCREW M5X6 6 10106C 39 FIXING PLATE 2 10106C...

Page 18: ...8360 Champ d Eau Montreal Quebec Canada H1P 1Y3 Tel 514 326 1161 Fax 514 326 5565 Parts Service Fax 514 326 5555 Order Desk orderdesk general ca www general ca 10 105CF M1 10 105 M1 Models 10 105 M1 1...