8. PORTS AND CONNECTIONS
KF Series pumps (see fig. 4) are provided with:
1. 2 inlet ports “IN”, 1” NPT-F
The line can be connected to either of the two inlet ports; the one not being used must be hermetically sealed.
2. 2 outlet ports “OUT”, Ø 1/2” NPT-F
3. 3 auxiliary ports; used for the pressure gauge only
9. PUMP INSTALLATION
9.1 Installation
The pump must be installed in a horizontal position using the correct threaded feet M 16 x 1.5; fasten the screws with a
torque value of 154.8 ft. lbs. (210 Nm).. The base must be perfectly flat and sufficiently rigid in order to avoid bending and
misalignments on the pump/transmission coupling axis due to the torque applied during operation. The unit must not be
rigidly fixed to the pavement, but requires the use of anti-vibration elements. For special applications contact the
Customer
Service Department
.
The pump is equipped with two lifting eyebolts to facilitate installation, as shown in the following figure.
In case of disassembly, to avoid allowing debris inside the front part of the crankcase, close the threaded hole with
the threaded cap.