In any case, oil must be changed at least once a year
since it may deteriorate by oxidation.
For room temperatures that differ from that mentioned earlier, follow the indications contained in the diagram
below, keeping in mind that the oil must have a minimum viscosity of 180 cSt.
VISCOSITY/ROOM TEMPERATURE DIAGRAM
Exhausted oil must be collected in an appropriate recipient and disposed of in appropriate locations.
In absolutely no case may it be dispersed into the environment.
GENERAL PUMP
A member of the Interpump Group
KFR SERIES
Set up the pumping system so that oil temperatures do not exceed in exceed 212° F (100° C) during pump
operation.
Use a temperature probe to be inserted into to oil drain plug, (Pos. 2 Fig. 3).
See “ATEX EXPLOSION PROTECTION” manual. ATTENTION: Use only oil with a flash point higher than
392° F (200° C).