SRM-6 Operation & Diagnostics
SRM-6 Maintenance Screen
076R176-000
SC SRM-6 Multiplexer
3-11
Issue 1
Installation & Operation Manual
SRM-6 Maintenance Screen
At the SRM-6 Main Menu, press
5
and then press
Enter
to access the Maintenance screen,
shown below.
describes the maintenance commands on this screen.
describes
the Firmware Download submenu.
Table 3-9
Maintenance Selections
Selection
Description
[1] Soft Reset
Causes the SRM-6 to perform a reset and resume operation using its
current configuration.
[2] Reset to Factory Defaults
Causes all options in the SRM-6 to return to their factory default
settings.
[3] Firmware Download
Activates the download function, described below.
[4] Copy Active file...
Makes a copy of the Active firmware and stores it as Standby firmware.
[5] Restore Active file...
Makes a copy of the Standby firmware, stores it as Active firmware and
then reboots the unit.
[0] Return to Main Menu
Exits the Maintenance menu and returns to the SRM-6 Main Menu.
SRM-6 Maintenance
[1] Soft Reset
[2] Reset to Factory Defaults
[3] Firmware Download
[4] Copy Active file to Standby
[5] Restore Active file from Standby then perform Soft Reset
[0] Return to Main Menu
Select: [ ]