Generac Power Systems XP8000E Owner'S Manual Download Page 4

2

Never store generator with fuel in tank where gasoline vapors 

• 

might reach an open flame, spark or pilot light (as on a furnace, 

water heater or clothes dryer). 

FIRE

 or 

EXPLOSION

 may 

result.

Generator exhaust gases contain 

• 

DEADLY

 carbon monoxide gas. 

This dangerous gas, if breathed in sufficient concentrations, can 

cause unconsciousness or even death. Operate this equipment 

only in the open air where adequate ventilation is available.

DANGER

  NEVER operate the generator indoors, in a garage, near an 

open window, or in an area that could accumulate exhaust 

gas.

Allow at least five (5) feet, or greater, of clearance on all sides 

• 

of generator or damage could be done to the unit. Never operate 

the unit inside any room or enclosure.

Never start or stop the unit with electrical loads connected 

• 

to receptacles AND with connected devices turned ON. Start 

the engine and let it stabilize before connecting electrical 

loads. Disconnect all electrical loads before shutting down the 

generator.

Do not insert objects through unit's cooling slots.

• 

Never operate generator: 

• 

 in rain; indoors or in any enclosed 

compartment; if connected electrical devices overheat; if 

electrical output is lost; if engine or generator sparks; if flames 

or smoke are observed while unit is running; if unit vibrates 

excessively.

NOTE:

This generator is equipped with a spark arrestor muffler. The 

spark arrestor must be maintained in effective working order by 

the owner/ operator. In the State of California, a spark arrestor 

is required by law (Section 4442 of the California Public 

Resources Code). Other states may have similar laws. Federal 

laws apply on federal lands.

Study these 

SAFETY RULES

 carefully before installing, operating 

or servicing this equipment. Become familiar with this manual 

and with the unit. The generator can operate safely, efficiently and 

reliably only if it is properly installed, operated and maintained. 

Many accidents are caused by failing to follow simple and 

fundamental rules or precautions.
The manufacturer cannot anticipate every possible circumstance 

that might involve a hazard. The warnings in this manual, and on 

tags and decals affixed to the unit are, therefore, not all inclusive. 

If using a procedure, work method or operating technique that the 

manufacturer does not specifically recommend, ensure that it is 

safe for others. Also make sure the procedure, work method or 

operating technique utilized does not render the generator unsafe.

DANGER

  Despite the safe design of this generator, 

operating this equipment imprudently, 

neglecting its maintenance or being careless 

can cause possible injury or death. Permit only 

responsible and capable persons to operate or 

maintain this equipment.

  Potentially lethal voltages are generated by 

these machines. Ensure all steps are taken to 

render the machine safe before attempting to 

work on the generator.

  Parts of the generator are rotating and/or hot 

during operation. Exercise care near running 

generators. Do not touch hot surfaces such as 

the muffler. Severe burns can occur on contact. 

Allow generator to cool before touching.

 GENERAL HAZARDS 

Never operate in an enclosed area or indoors.

• 

For safety reasons, the manufacturer recommends that the 

• 

maintenance of this equipment is carried out by an Authorized 

Dealer.

The engine exhaust fumes contain carbon monoxide, which 

• 

can be DEADLY. This dangerous gas, if breathed in sufficient 

concentrations, can cause unconsciousness or even death.  This 

exhaust system must be properly maintained. Do nothing that 

might render the exhaust system unsafe or in noncompliance 

with any local codes and/or standards.

Keep hands, feet, clothing, etc., away from drive belts, fans, 

• 

and other moving or hot parts. Never remove any fan guard 

while the unit is operating.

Adequate, unobstructed flow of cooling and ventilating air 

• 

is critical to correct generator operation. Do not alter the 

installation or permit even partial blockage of ventilation 

provisions, as this can seriously affect safe operation of the 

generator. The generator MUST be operated outdoors.

IMPORTANT SAFETY INSTRUCTIONS
Portable Generator System

  SAVE THESE INSTRUCTIONS – The manufacturer suggests that these rules for safe operation be copied and posted near the unit's 

installation site. Safety should be stressed to all operators and potential operators of this equipment.

The engine exhaust from this product contains 

chemicals known to the state of California to cause 

cancer, birth  defects or other reproductive harm.

WARNING

This product contains or emits chemicals

known to the state of California to cause

cancer, birth defects or other reproductive harm.

WARNING

Summary of Contents for XP8000E

Page 1: ...OTING WARRANTY www generac com or 1 888 GENERAC XP Professional Series Portable Generator COMMERCIAL INDUSTRIAL RESIDENTIAL MODELS 005606 0 XP8000E 005605 0 XP6500E 8 000 Watt Portable Generator 6 500...

Page 2: ...g Gasoline 8 2 8 To Start the Engine 8 2 9 Stopping the Engine 9 2 10 Low Oil Pressure Shutdown System 9 2 10 1 Initial Start up 9 2 10 2 Sensing Low Oil Pressure 9 2 10 3 Restarting 9 2 11 Charging a...

Page 3: ...ate the unit This prepares them if they need to operate the equipment in an emergency DANGER Using a generator indoors WILL KILL YOU IN MINUTES Exhaust contains carbon monoxide a poison gas you cannot...

Page 4: ...method or operating technique that the manufacturer does not specifically recommend ensure that it is safe for others Also make sure the procedure work method or operating technique utilized does not...

Page 5: ...g injury FIRE HAZARDS For fire safety the generator must be operated and maintained properly Operation must always comply with applicable codes standards laws and regulations Adhere strictly to local...

Page 6: ...rs is needed for assembling the wheel kit NOTE The wheel kit is not intended for over the road use Refer to Figure 2 and install the wheel kit as follows Generator will be resting on an accessory box...

Page 7: ...breaker to protect the generator against electrical overload The 30 Amp receptacle is protected by a 2 pole lever circuit breaker rated at 27 1 Amps for the XP6500E and 30 Amps for the XP8000E 5 Hour...

Page 8: ...ed 2400 watts 2 4 kW or 20 Amps of current Use only high quality well insulated 3 wire grounded cord sets rated for 125 Volts at 20 Amps or greater Keep extension cords as short as possible preferably...

Page 9: ...is surge of power lasts only a few seconds when starting such motors Make sure to allow for high starting wattage when selecting electrical devices to connect to the generator 1 Figure the watts neede...

Page 10: ...t overfill the fuel tank Always leave room for fuel expansion Wipe up any spilled fuel immediately Use regular UNLEADED gasoline with the generator engine Do not use premium gasoline Do not mix oil wi...

Page 11: ...SURE SHUTDOWN SYSTEM The engine is equipped with a low oil pressure sensor that shuts down the engine automatically when the oil pressure drops below 5 psi If the engine shuts down by itself and the f...

Page 12: ...l Type See Chart in Adding Engine Oil Section Oil Capacity w Filter Change 1 5 Qts w o Filter Change 1 2 Qts Run Time Fuel Consumption 1 2 Load 8 kW 12 Hours 73 gallons per hour 6 5 kW 14 Hours 64 gal...

Page 13: ...e the engine is still warm Clean area around oil drain plug Remove oil drain plug from engine and oil fill plug to drain oil completely into a suitable container When oil has completely drained instal...

Page 14: ...CLEARANCE After the first 50 hours of operation check the valve clearance in the engine and adjust if necessary Important If feeling uncomfortable about doing this procedure or the proper tools are n...

Page 15: ...idic gas can damage the fuel system of an engine while in storage To avoid engine problems the fuel system should be emptied before storage of 30 days or longer as follows Remove all gasoline from the...

Page 16: ...ld down bracket Disconnect the RED battery cable to the battery Positive terminal Disconnect the BLACK battery cable to the battery Negative terminal To install a new battery Reverse the steps above a...

Page 17: ...ed 12 Engine has lost compression 1 Turn Fuel shut off ON 2 Clean or replace air cleaner 3 Fill fuel tank 4 Drain fuel tank and fill with fresh fuel 5 Connect wire to spark plug 6 Replace spark plug 7...

Page 18: ...You are responsible for contacting a Generac Authorized Warranty Dealer as soon as a problem occurs The warranty repairs should be completed in a reasonable amount of time not to exceed 30 days Warra...

Page 19: ...led replacement point for that part If the part fails prior to the first scheduled replacement the part shall be repaired or replaced by Generac according to Subsection 4 below Any such emissions rela...

Page 20: ...d adjustments Failures caused by any contaminated fuels oils or lack of proper oil levels Repairs or diagnostics performed by individuals other than Guardian Generac authorized dealers not authorized...