EMERGENCY STOP SWITCH
This unit is equipped with an emergency stop switch. The switch is located on the outside of the rear enclosure panel.
See
. Activate the switch by pressing the red button in until it locks down. This will stop the engine. The
switch will remain locked until the button is pulled out.
CAUTION
Equipment Damage. The emergency stop switch is not to be used to power down the unit
under normal operating circumstances. Doing so will result in equipment damage. (000246)
TOWING THE TRAILER
Note:
See
before towing a trailer.
1. Use the jack to raise or lower the trailer onto the hitch of the towing vehicle. Lock the hitch coupling and attach
the safety chains or cables to the vehicle. Raise the jack foot completely.
2.
Connect any trailer wiring to the tow vehicle. Check for proper operation of the directional and brake lights.
3.
Make sure all doors are properly latched.
4.
Check for proper inflation of the trailer tires. For maximum tire pressures, see
.
5.
Check the wheel lugs. Tighten or replace any that are loose or missing. If a
tire has been removed for axle service or replaced, tighten the lugs in the
order shown to the following specifications:
6.
Start all lug nuts by hand.
a. First pass tighten to 20-25 ft-lbs (27-33 Nm).
b. Second pass tighten to 50-60 ft-lbs (67-81 Nm).
c. Third pass tighten to 90-120 ft-lbs (122-162 Nm).
Note:
After the first road use, repeat tightening procedure.
Figure 15 - Lug Sequence
1
2
3
4
5
6
7
8
00670