Operation
36833 C
MGG100M Operating Manual
31
Use the charts as follows.
1. Locate required flow in the left hand column. If it falls between two numbers, use the larger.
2. Determine total required pipe length.
3. Read chart from left to right to find the total length equal to or greater than the distance from source to use.
4. From that point, read up to find the required pipe size.
Table 2 - LP Liquid Line Sizing Chart
Liquid
Propane
Flow
Iron Pipe Size (Diameter)
1/4”
3/8”
1/2”
3/4”
1”
1-1/4”
1-1/2”
Schedule
Schedule
Schedule
Schedule
Schedule
Schedule
Schedule
GPH
40
80
40
80
40
80
40
80
40
80
40
80
40
80
10
729
416
15
324
185
20
182
104
825
521
40
46
26
205
129
745
504
60
20
11
92
58
331
224
80
11
6
51
32
187
127
735
537
100
7
4
33
21
119
81
470
343
120
23
15
83
56
326
238
140
15
9
61
41
240
175
813
618
160
13
8
47
32
184
134
623
473
180
37
25
145
106
491
373
200
30
20
118
86
399
303
240
21
14
81
59
277
211
280
15
10
60
44
204
155
300
13
9
52
38
177
135
785
623
350
38
28
130
99
578
459
400
30
22
99
75
433
344
980
794
Summary of Contents for Magnum MGG100M
Page 4: ...This Page Intentionally Left Blank 36833 C MGG100M Operating Manual iv...
Page 8: ...This Page Intentionally Left Blank 36833 C MGG100 Operating Manual viii...
Page 14: ...Safety 6 MGG100M Operating Manual 36833 C This Page Intentionally Left Blank...
Page 52: ...Operation 44 MGG100M Operating Manual 36833 C This Page Intentionally Left Blank...
Page 76: ...Wiring Diagrams 68 MGG100M Operating Manual 36833 C This Page Intentionally Left Blank...
Page 83: ......