23

2.  NO sobrecargue el generados; si el LED rojo de “sobrecarga” 

se enciende y los accesorios conectados al generador dejan de 
funcionar, detenga el motor y reduzca la carga del generador. Reinicie 
y reduzca las cargas.

3.  Consulte la siguiente tabla para estimar lo que el generador puede 

alimentar.

Dispositivo  ...................................................Vatios en funcionamiento

*Aire acondicionado (12,000 Btu) ..................................................1700
*Aire acondicionado (24.000 Btu) ..................................................3800
*Aire acondicionado (40.000 Btu) ..................................................6000
Cargador de baterías (20 Amp) ........................................................500
Lijadora de bandas (3”) ..................................................................1000
Sierra eléctrica ...............................................................................1200
Sierra circular (6-1/2”) .................................................... de 800 a 1000
*Secadora de ropa (Eléctrica) ........................................................5750
*Secadora de ropa (a gas) ...............................................................700
*Lavadora de ropa .........................................................................1150
Cafetera .........................................................................................1750
*Compresor (1 HP) ........................................................................2000
*Compresor (3/4 HP) .....................................................................1800
*Compresor (1/2 HP) .....................................................................1400
Rizador de pelo ............................................................................... 700
*Deshumedecedor ...........................................................................650
Lijadora de disco (9”) ....................................................................1200
Cortadora ........................................................................................500
Frazada eléctrica ..............................................................................400
Pistola eléctrica de clavos ..............................................................1200
Rango eléctrico (por elemento).......................................................1500
Sartén eléctrica ..............................................................................1250
*Congeladora ..................................................................................700
*Ventilador de chimenea(3/5 HP) .....................................................875
*Garaje de apertura automática ......................................... de 500 a 750
Secador de pelo .............................................................................1200
Taladro de mano ............................................................. de 250 a 1100
Cortador de setos ............................................................................450
Herramienta de impacto ...................................................................500
Plancha .........................................................................................1200
* Eyector .........................................................................................800
Cortadora de césped ......................................................................1200
Bombilla de luz.................................................................................100
Horno de microondas ...................................................... de 700 a 1000
*Enfriador de leche ........................................................................1100
Quemador de aceite sobre chimenea ................................................300
Calentador de chispa de aceite (140,000 Btu) ...................................400
Calentador de chispa de aceite (85.000 Btu) .....................................225
Calentador de chispa de aceite (30.000 Btu) .....................................150
*Pulverizador de pintura, sin aire (1/3 HP) ........................................600
Pulverizador de pintura, sin aire (de mano) .......................................150
Radio .................................................................................. de 50 a 200
*Refrigeradora .................................................................................700
Cocina lenta  ....................................................................................200
*Bomba sumergible (1-1/2 HP) ......................................................2800
*Bomba sumergible (1 HP) ............................................................2000
*Bomba sumergible (1/2 HP) .........................................................1500
*Bomba de desagüe ....................................................... de 800 a 1050

* Calcule 3 veces la potencia de funcionamiento de la lista para arrancar 
estos dispositivos.

NOTA:

Cuando se arranca un motor eléctrico, el LED de “SOBRECARGA” 
puede encenderse hasta por 5 segundos (esto es normal). Si 
permanece encendido, ha ocurrido una falla. Retire todas las cargas 
y apague el generador para reiniciar la alarma. Reinicie el generador. 
Si el LED de “SOBRECARGA” permanece encendido, pida ayuda al 
concesionario de Generac.

2.4  USO DEL INTERRUPTOR 

FLEXPOWER™

Cuando los accesorios conectados al generador vayan a ser usados en 
forma intermitente (como un taladro de mano), el interruptor FlexPower™ 
puede colocarse en la posición “ON” (I).  Esto disminuirá la velocidad 
del motor del generador cuando las cargas no se apliquen, ahorrando 
combustible, reduciendo el desgaste del motor y extendiendo el tiempo 
de funcionamiento.

2.5 APAGADO

Una vez que el generador no sea necesario, puede apagarse.

1.  Apague todos los accesorios conectados al generador. Desconecte 

todos los cables que vayan a las salidas dúplex de 120 VAC o el 
conector de 12 VCC.

2.  Gire la válvula de combustible a la posición OFF (O) (figura 7). Un 

interruptor detrás de la válvula de combustible conecta a tierra el 
sistema de ignición, deteniendo el motor y cerrando el abastecimiento 
de combustible.

3.  Cierre la ventilación en la tapa de combustible.
4.  Deje enfriar el generador antes de moverlo o almacenarlo.

Figura 7 - Cierre de combustible

CERRAR COMBUSTIBLE

CUIDADO

 Deje enfriar el generador antes de 

almacenarlo. Las altas temperaturas estarán 

presentes en la parte de atrás de la unidad por 

algún tiempo luego del apagado.

Operación

Summary of Contents for IX 800

Page 1: ...rter Generator Operator s Manual MODEL 005791 3 DEADLY EXHAUST FUMES ONLY use OUTSIDE far away from windows doors and vents NOT INTENDED FOR USE IN CRITICAL LIFE SUPPORT APPLICATIONS SAVE this Manual...

Page 2: ...7 Clean Spark Arrestor Screen 10 3 8 Transportation and Storage 11 Troubleshooting 12 4 1 Troubleshooting Guide 12 Notes 13 iX 800 Manual del operador del Generador Inversor Digital 15 iX 800 Manuel...

Page 3: ...zardous situation or action which if not avoided will result in death or serious injury Indicates a hazardous situation or action which if not avoided could result in death or serious injury Indicates...

Page 4: ...er while barefoot or while hands or feet are wet DANGEROUS ELECTRICAL SHOCK MAY RESULT The National Electric Code NEC requires the frame and external electrically conductive parts of the generator be...

Page 5: ...CONSTRUCTION AND SAFETY CODE available from www nfpa org 3 International Building Code available from www iccsafe org 4 Agricultural Wiring Handbook available from www rerc org Rural Electricity Resou...

Page 6: ...ife This engine is certified to operate on gasoline The emission control system on your generator consists of the following Fuel Metering System Ignition System Carburetor Spark plug Fuel Pump Ignitio...

Page 7: ...n or permit even partial blockage of ventilation provisions as this can seriously affect safe operation of the generator The generator MUST be operated outdoors This exhaust system must be properly ma...

Page 8: ...st the choke to approximately the position until the engine begins to run smoothly then push the lever all the way to the left Figure 6 8 Make sure the bottom of the generator is not blocked by sand l...

Page 9: ...ded it can be shut down 1 Switch off any accessories connected to the generator Unplug any cords to the 120 VAC duplex outlets 2 Turn the fuel valve to the OFF O position Figure 7 A switch behind the...

Page 10: ...expected operating temperature Above 40 F use SAE 30 Below 40 F to 10 F use 10W 30 Below 10 F use synthetic 5W 30 10W 30 10W 30 SAE 30 SAE 30 Synthetic 5W 30 Synthetic 5W 30 2 8 1 TO ADD ENGINE OIL TO...

Page 11: ...operation Clean the air filter more often if operating in dusty or sandy conditions Replace as necessary Inspect and clean every 50 hours of operation 3 3 CLEANING THE GENERATOR 1 Use a damp cloth to...

Page 12: ...t in Section ADDING ENGINE OIL then replace the drain plug 3 6 CHANGING THE SPARK PLUG Replace the spark plug each year regardless of how many hours the generator has been run Use a NGK CR7HSA that ha...

Page 13: ...emove all gasoline from the fuel tank 2 Start and run engine until engine stops from lack of fuel or open the valve on carburetor bowl Figure 13 and allow gasoline to drain down tube into a receptacle...

Page 14: ...e FlexPower switch 1 Turn choke off 2 Clean or replace the air filter element 3 Replace spark plug 4 Replace FlexPower switch No AC output 1 Generator is overloaded OVERLOAD LED is on 2 AC voltage is...

Page 15: ...13 Notes...

Page 16: ...Manual Part No 0J4113 Rev D 06 25 13 Printed in China...

Page 17: ...r Digital MODELO 005791 3 PELIGRO HUMOS DE ESCAPE MORTALES Util celo SOLAMENTE al AIRE LIBRE y lejos de ventanas puertas y respiraderos NO DISE ADO PARA SER USADO EN APLICACIONES DE SOPORTE DE VIDA CR...

Page 18: ...uj a 26 3 7 Limpie el filtro de supresor de chispas 27 3 8 Transporte y almacenamiento 27 Detecci n de problemas 28 4 1 Gu a de detecci n de problemas 28 Notas 29 CAJA DE ACCESORIOS Revise todo el con...

Page 19: ...bre instrucciones especiales sobre una operaci n en particular que puede ser peligrosa si se ejecuta en forma incorrecta o sin cuidado Obs rvelas con cuidado Sus definiciones son como sigue PELIGRO In...

Page 20: ...ctrico ni dispositivo mientras est de pie sobre agua con los pies descalzos o con las manos o pies h medos PUEDE HABER UNA DESCARGA EL CTRICA COMO RESULTADO El C digo El ctrico Nacional NEC requiere q...

Page 21: ...en www nfpa org 3 El C digo internacional de la construcci n disponible en www iccsafe org 4 Manual de Cableado Agr cola disponible en www rerc org Consejo de Recursos de Electricidad Rural P O Box 30...

Page 22: ...de control de emisiones de su generador consiste en lo siguiente Sist medici n de combustible Sistema de arranque Carburador Buj a Bomba de combustible M dulo de arranque L neas de combustible Sistem...

Page 23: ...UNCA lo use en el hogar en un veh culo o en reas parcialmente cerradas como garajes a n si las puertas y ventanas est n abiertas selo S LO en exteriores y lejos de ventanas abiertas puertas ductos de...

Page 24: ...lvula 90 en sentido antihorario a la posici n ON I 2 Tire del centro de la tapa de llenado de combustible y purgue el sistema de combustible presionando el mbolo hasta cinco 5 veces con la ventilaci...

Page 25: ...0 Cocina lenta 200 Bomba sumergible 1 1 2 HP 2800 Bomba sumergible 1 HP 2000 Bomba sumergible 1 2 HP 1500 Bomba de desag e de 800 a 1050 Calcule 3 veces la potencia de funcionamiento de la lista para...

Page 26: ...desparramarse sobre el motor caliente y causar un INCENDIO o una EXPLOSI N Limpie los derrames de combustible inmediatamente 2 7 1 PARA LLENAR EL TANQUE DE COMBUSTIBLE 1 Retire la tapa del tanque de c...

Page 27: ...retenida en vac os o grietas del aislamiento del bobinado del rotor y estator La acumulaci n del agua y el polvo en los bobinados internos del generador eventualmente disminuir n la resistencia de ais...

Page 28: ...etida de la piel con el aceite usado Lave a fondo las reas expuestas con jab n Cambie el aceite del motor despu s de las primeras cinco 5 horas de operaci n Despu s cambie el aceite del motor cada 100...

Page 29: ...separaci n y formaci n de cidos que pueden da ar el sistema de combustible del motor durante el almacenamiento Para evitar problemas con el motor se recomienda el uso de un estabilizador comercial de...

Page 30: ...ptor FlexPower defectuoso 1 Cierre el choke 2 Limpie o reemplace el elemento del filtro de aire 3 Reemplace la buj a 4 Reemplace el interuptor FlexPower No hay salida AC 1 El generador est sobrecargad...

Page 31: ...29 Notas...

Page 32: ...Manual Parte No 0J4113 Rev D 25 06 13 Impreso en China...

Page 33: ...inverseur num rique MOD LE 005791 3 GAZ D CHAPPEMENT MORTEL Utiliser UNIQUEMENT L EXT RIEUR loin des fen tres portes et vents L UTILISATION N EST PAS PR VUE POUR LES MOYENS D ENTRETIEN ARTIFICIEL DE...

Page 34: ...gie d allumage 42 3 7 Nettoyes l cran du pare tincelles 43 3 8 Transport et stockage 43 D pannage 44 4 1 Guide de d pannage 44 Remarques 45 BO TE D ACCESSOIRES V rifier le contenu de la bo te Si des p...

Page 35: ...especter attentivement Leurs d finitions sont les suivantes Indique une situation ou une action dangereuse qui si elle n est pas vit e entra nera la mort ou des blessures graves AVERTISSEMENT Indique...

Page 36: ...ui est dans l eau alors que vous tes pieds nus ou que vos mains ou vos pieds sont mouill s CELA ENTRA NERA UN RISQUE D LECTROCUTION Le National Electric Code Code lectrique national exige que le b ti...

Page 37: ...ING CONSTRUCTION AND SAFETY CODE disponible aupr s de www nfpa org 3 International Building Code disponible aupr s de www iccsafe org 4 Agricultural Wiring Handbook disponible aupr s de www rerc org R...

Page 38: ...r le des missions de votre g n rateur est compos des l ments suivants Syst me de dosage du carburant Syst me d allumage Carburateur Bougie d allumage Pompe carburant Module d allumage Tuyaux de carbur...

Page 39: ...ouvertes Utiliser UNIQUEMENT l ext rieur et loin des fen tres portes ouvertes ventilations et dans un espace dans lequel le gaz d chappement ne s accumulera pas de fa on mortelle Les fum es d chappeme...

Page 40: ...vrir l vent du r servoir d essence situ au dessus du bouchon de remplissage du carburant en tournant la partie centrale vers l indication ON Sch ma 5 4 Si le moteur est froid ou s il n a pas tourn dep...

Page 41: ...rrer le g n rateur Si la DEL de SURCHARGE reste allum e contacter un d positaire Generac pour obtenir de l aide 2 4 UTILISATION DE L INTERRUPTEUR FLEXPOWER Lorsque les accessoires connect s au g n rat...

Page 42: ...IR LE R SERVOIR JUSQU A CE QUE LE NIVEAU DU CARBURANT SE SITUE DEUX 2 POUCES DU COL DE REMPLISSAGE 3 Remettre le bouchon du r servoir d essence S assurer que la vanne du bouchon du r servoir se trouve...

Page 43: ...ment la r sistance d isolement de ces bobinages 3 2 PROGRAMME DE MAINTENANCE DU G N RATEUR Respecter le programme d entretien recommand pour commander des pi ces de rechange appeler le 1 888 436 3722...

Page 44: ...avon Changer l huile du moteur apr s les cinq 5 premi res heures de fonctionnement Par la suite changer l huile du moteur toutes les 100 heures Pour changer l huile du moteur ATTENTION Changer l huile...

Page 45: ...euvent endommager le syst me de carburant d un moteur pendant le stockage Pour viter les probl mes de moteur il est recommand d utiliser un stabilisateur d essence commercial avant le stockage Respect...

Page 46: ...r la position Arr t 2 Nettoyer ou remplacer l l ment du filtre air 3 Remplacer la bougie d allumage 4 Remplacer l interrupteur FlexPower Absence de sortie CA 1 Le g n rateur est en surcharge la DEL DE...

Page 47: ...45 Remarques...

Page 48: ...Manuel partie n 0J4113 R v D 25 06 13 Imprim en Chine...

Page 49: ...thereafter be considered a non consumer use generator for the purpose of this warranty All warranty expense allowances are subject to the conditions defined in Generac s Service Policy Manual THIS WAR...

Page 50: ...e contact Allpower by phone at 1800 333 428 or visit Allpower s website at www allpower com au FOR NEW ZEALAND ONLY Nothing in this warranty statement excludes restricts or modifies any condition warr...

Page 51: ...ugar del servicio p blico donde el servicio p blico se encuentre presente o donde el servicio p blico de energ a no exista normalmente Una vez que el generador ha experimentado uso comercial o de alqu...

Page 52: ...da o razonable previsible Usted tambi n tiene derecho a que los productos sean reparados o sustituidos si los productos no son de calidad aceptable y la falla no llega a ser una falla mayor Para cons...

Page 53: ...au lieu du r seau lorsque le r seau lectrique principal est pr sent ou n existe normalement pas Une fois que la g n ratrice a t utilis e de mani re commerciale ou locative elle sera consid r e par la...

Page 54: ...t la r paration ou au remplacement si les produits ne sont pas d une qualit acceptable et si cette d faillance n est pas consid r e comme majeure Pour tout renseignement suppl mentaire sur les produit...

Reviews: