5

1.3 EMISSIONS INFORMATION

The Environmental Protection Agency requires that this generator 

comply with exhaust and evaporative emission standards. This 

generator is certified to operate on gasoline. The emission control 

system includes the following components:
•  Air Induction System

 

– Intake Pipe / Manifold

 

– Air Cleaner

• Fuel System

 

– Carburetor

 

– Fuel Tank / Cap

 

– Fuel Lines

 

– Evaporative Vent Lines

• Ignition System

 

– Spark Plug

 

– Ignition Module

• Exhaust System

 

– Exhaust Manifold

 

– Muffler

2.1  KNOW THE GENERATOR

Read the Owner’s Manual and Safety Rules before operating 

this generator.

Compare the generator to Figures 2 through 4 to become 

familiarized with the locations of various controls and adjustments. 

Save this manual for future reference.

1.  120 Volt AC, 20 Amp, Duplex Receptacle

 – Supplies electrical 

power for the operation of 120 Volt AC, 20 Amp, single-phase, 

60 Hz electrical lighting, appliance, tool and motor loads.

2.  120/240 Volt AC, 30 Amp Locking Receptacle

 – Supplies 

electrical power for the operation of 120 and/or 240 Volt AC, 

30 Amp, single-phase, 60 Hz, electrical lighting, appliance, 

tool and motor loads.

3.  Circuit Breakers (AC)

 – Each receptacle is provided with a 

push-to-reset circuit breaker to protect the generator against 

electrical overload.

4. Oil Drain

 – Use to drain engine oil.

5. Air Filter

 – Filters intake air as it is drawn into the engine.

6. Choke Knob

 – Used when starting a cold engine.

7. Fuel Tank

 – See generator Specifications for tank capacity.

8. Grounding Lug

 – Ground the generator to an approved earth 

ground here. See "Grounding the Generator" for details.

9. Run/Stop Switch

 – Controls the operation of the generator 

(pull start models).

9A. Start Switch

 – Used to start engine from the starter motor 

(electric start models only).

10. Muffler

 – Quiets the engine.

11. Handle

 – Pivot and retract for storage. Press the spring-

loaded button to move handles.

12. Gas Cap

 – Fuel fill location.

13. Fuel Gauge

 – Shows fuel level in tank.

14. Oil Fill

 – Add oil here.

15. Recoil Starter

 – Use to start engine manually.

16. Fuel Shut Off

 – Valve between fuel tank and carburetor.

17. Roll Over Valve

 – Passes fuel to the engine airbox.

18. Recovery Hose

 – Install between the carbon canister and the 

roll over valve.

19. Hourmeter

 – Tracks hours of operation.

20.  Battery Charger Input

 – This receptacle allows the capability 

to recharge the 12 volt DC storage battery provided with 

the 12 Volt Adaptor Plug Charger which is included in the 

Accessory Box. Located behind the battery charger input is 

a 1.50 Amp in-line fuse which is inside the control panel to 

protect the battery (electric start models only).

21.  Battery

 – Powers the electric starter (electric start models 

only).

Figure 2 - Control Panel

20

9A

19

2

3

1

Figure 3 - Generator Controls

17

18

6

5

11

15

16

Operation

Summary of Contents for G0059395

Page 1: ...or www generac com or 1 888 436 3722 DEADLY EXHAUST FUMES ONLY use OUTSIDE far away from windows doors and vents NOT INTENDED FOR USE IN CRITICAL LIFE SUPPORT APPLICATIONS SAVE this Manual Provide thi...

Page 2: ...g Gasoline 9 2 8 Starting Pull Start Engines 10 2 9 Starting Electric Start Engines 10 2 10 Stopping the Engine 11 2 11 Low Oil Level Shutdown System 11 2 11 1 Sensing Low Oil Level 11 2 12 Charging t...

Page 3: ...definitions are as follows INDICATES A HAZARDOUS SITUATION OR ACTION WHICH IF NOT AVOIDED WILL RESULT IN DEATH OR SERIOUS INJURY Indicates a hazardous situation or action which if not avoided could re...

Page 4: ...frame and external electrically conductive parts of the generator be properly connected to an approved earth ground Local electrical codes may also require proper grounding of the generator Consult wi...

Page 5: ...rc org Rural Electricity Resource Council P O Box 309 Wilmington OH 45177 0309 5 ASAE EP 364 2 Installation and Maintenance of Farm Standby Electric Power available from www asabe org American Society...

Page 6: ...nd install the Frame Foot and Rubber Bumpers as shown Slide the Rubber Bumper studs through the Frame Foot then install the Locking Flange Nuts Slide the Hex Head Bolts through the holes in the Frame...

Page 7: ...to drain engine oil 5 Air Filter Filters intake air as it is drawn into the engine 6 Choke Knob Used when starting a cold engine 7 Fuel Tank See generator Specifications for tank capacity 8 Grounding...

Page 8: ...the meter is tracking hours of operation Figure 5 Hourmeter HOUR GLASS GRAPHIC RESET BUTTON IF EQUIPPED 0000 0 2 3 CORD SETS AND CONNECTION PLUGS 2 3 1 120 VAC 20 AMP DUPLEX RECEPTACLE This is a 120...

Page 9: ...RTABLE This generator has an equipment ground that connects the generator frame components to the ground terminals on the AC output receptacles see NEC 250 34 A for explanation This allows the generat...

Page 10: ...or does not give wattage multiply volts times ampere rating to determine watts volts x amps watts Some electric motors such as induction types require about three times more watts of power for startin...

Page 11: ...GASOLINE Never fill fuel tank indoors Never fill fuel tank when engine is running or hot Avoid spilling gasoline on a hot engine Allow engine to cool entirely before filling fuel tank DO NOT light a c...

Page 12: ...d repeat starting instructions IMPORTANT Do not overload the generator Also do not overload individual panel receptacles These outlets are protected against overload with push to reset type circuit br...

Page 13: ...hen the oil level drops below a specified level If the engine shuts down by itself and the fuel tank has enough gasoline check engine oil level 2 11 1 SENSING LOW OIL LEVEL If the system senses a low...

Page 14: ...31 inch or 0 70 0 80 mm Gasoline Capacity 25 6 Liters 6 77 U S gallons Oil Type See Chart in Before Starting the Generator Section Oil Capacity 1 Liters 1 06 Qts Run Time at 50 Load 10 Hours 7 5kW Dis...

Page 15: ...urns Allow engine to cool before draining oil Avoid prolonged or repeated skin exposure with used oil Thoroughly wash exposed areas with soap Use the following instructions to change the oil after the...

Page 16: ...leads to separation and formation of acids during storage Acidic gas can damage the fuel system of an engine while in storage To avoid engine problems the fuel system should be emptied before storage...

Page 17: ...9 Low oil level 10 Excessive rich fuel mixture 11 Intake valve stuck open or closed 12 Engine has lost compression 1 Turn Fuel Shut off ON 2 Clean or replace air filter 3 Fill fuel tank 4 Drain fuel...

Page 18: ...Manual Part No 0K0173 Rev B 01 24 13 Printed in China...

Page 19: ...Manual Parte No 0K0173 Rev B 24 01 13 Impreso en China...

Page 20: ...e combustible demasiado rica 11 V lvula de entrada atascada o cerrada 12 El motor ha perdido compresi n 1 Gire el cierre de combustible a ON 2 Limpie o reemplace el filtro de aire 3 Llene el tanque de...

Page 21: ...urante el almacenamiento Los gases cidos pueden da ar el sistema de combustible de un motor durante el almacenamiento Para evitar problemas con el motor el sistema de combustible deber vaciarse antes...

Page 22: ...ta que el motor enfr e antes de drenar el aceite Evite una exposici n prolongada o repetida de la piel con el aceite usado Lave completamente las reas expuestas con jab n Use las siguientes instruccio...

Page 23: ...84420101 Espaciamiento de la buj a 0 028 0 031 pulgadas o 0 70 0 80 mm Capacidad de gasolina 25 6 L 6 77 galones americanos Tipo de aceite Ver la cartilla en la secci n Antes de arrancar el generador...

Page 24: ...forma autom tica cuando el nivel de aceite cae por debajo de un nivel especificado Si el motor se apaga y el tanque de combustible tiene suficiente gasolina revise el nivel de aceite de motor 2 11 1 S...

Page 25: ...nerador Asimismo no sobrecargue los recept culos individuales Estas tomas est n protegidas contra sobrecargas con interruptores de circuito tipo presionar para reiniciar Si la corriente nominal de cua...

Page 26: ...motor est funcionando o est caliente Evite derramar gasolina sobre un motor caliente Deje enfriar al motor completamente antes de llenar el tanque de combustible NO encienda cigarrillos o fume cuando...

Page 27: ...es para determinar los vatios volts x amps vatios Algunos motores el ctricos como los del tipo inducci n requieren alrededor de tres veces m s potencia para arrancar que para funcionar Este transitori...

Page 28: ...odore NE JAMAIS utiliser la g n ratrice l int rieur d une r sidence ou d un garage M ME SI les portes et les fen tres sont ouvertes Utiliser uniquement L EXT RIEUR et loin des fen tres portes et vents...

Page 29: ...as horas de operaci n Figura 5 Hor metro GR FICO DE RELOJ DE ARENA BOT N DE REINICIO SI EST INSTALADO 0000 0 2 3 JUEGO DE CABLES Y CONECTORES 2 3 1 RECEPT CULO DUPLEX DE 120 VAC 20 AMP Esta es una tom...

Page 30: ...el fin de proteger al generador contra sobrecargas el ctricas 4 Drenaje de aceite Usar para drenar el aceite del motor 5 Filtro de aire Filtra el aire de ingreso al motor 6 Palanca de choke Se le usa...

Page 31: ...goma como se muestra Deslice los tacos del parachoques de goma a trav s de la pata del marco luego instale las contratuercas de cierre Deslice los pernos de cabeza hexagonal a trav s de los agujeros d...

Page 32: ...rerc org Consejo de Recursos de Electricidad Rural P O Box 309 Wilmington OH 45177 0309 5 ASAE EP 364 2 Instalaci n y mantenimiento de energ a el ctrica de respaldo en granjas disponible en www asabe...

Page 33: ...nas que son conductores el ctricos est n conectadas apropiadamente a una conexi n a tierra aprobada Los c digos el ctricos locales pueden asimismo requerir una apropiada conexi n a tierra del generado...

Page 34: ...TRAER COMO RESULTADO LA MUERTE O UN DA O SERIO ADVERTENCIA Indica una situaci n peligrosa o acci n que si no se evita podr a traer como resultado la muerte o un da o serio CUIDADO Indica una situaci n...

Page 35: ...Arranque de motores de recule 10 2 9 Arranque de motores con arranque el ctrico 10 2 10 Detener el Motor 11 2 11 Sistema de apagado por bajo nivel de aceite 11 2 11 1 Sensando el nivel de aceite 11 2...

Page 36: ...ARANT A LIMITADA DOS A OS DOS A OS PELIGRO HUMOS DE ESCAPE MORTALES Util celo SOLAMENTE al AIRE LIBRE y lejos de ventanas puertas y respiraderos NO DISE ADO PARA SER USADO EN APLICACIONES DE SOPORTE D...

Reviews: