 10 

2.8  STARTING PULL START ENGINES



 Never start or stop engine with electrical 

devices plugged into the receptacles AND 

devices turned on.

1.  Unplug all electrical loads from the unit's receptacles before 

starting the engine.

2.  Make sure the unit is in a level position (not to exceed 15° in 

any direction).

3.  OPEN the Fuel Shut-off Valve (Figure 10).
4.  Turn engine RUN/STOP switch to ON position (Figure 11).
5.  Slide engine choke to the LEFT to FULL CHOKE position 

(Figure 12).

6.  To start engine, firmly grasp the recoil handle and pull slowly 

until increased resistance is felt. Pull rapidly up and away.

7.  When engine starts, move choke knob to 1/2-CHOKE position 

until engine runs smoothly and then fully into RUN position. 

If engine falters, move choke back out to 1/2-CHOKE position 

until engine runs smoothly and then to RUN position.

NOTE:

If engine fires, but does not continue to run, move choke lever 

to FULL CHOKE and repeat starting instructions.
IMPORTANT:

 Do not overload the generator. Also, do not overload 

individual panel receptacles. These outlets are protected against 

overload with push-to-reset-type circuit breakers. If amperage 

rating of any circuit breaker is exceeded, that breaker opens and 

electrical output to that receptacle is lost. Read “Don’t Overload the 

Generator” carefully.

Figure 10 - Fuel Shut-off Valve

Figure 11 - Engine ON/OFF Switch

Figure 12 - Choke Position

CHOKE LEVER

LEFT = CHOKE (START)

RIGHT = RUN

2.9  STARTING ELECTRIC START ENGINES



 Never start or stop engine with electrical 

devices plugged into the receptacles AND 

devices turned on.

1.  Unplug all electrical loads from the unit's receptacles before 

starting the engine.

2.  Make sure the unit is in a level position (not to exceed 15° in 

any direction).

3.  Open the fuel shut-off valve (Figure 10).
4.  Move engine CHOKE knob outward to FULL CHOKE position 

(Figure 12).

5.  To start engine, press and hold the Start/Run/Stop switch in 

the “Start” position. The engine will crank and attempt to start. 

When the engine starts, release the switch to the run position.

Operation

Summary of Contents for G0059395

Page 1: ...or www generac com or 1 888 436 3722 DEADLY EXHAUST FUMES ONLY use OUTSIDE far away from windows doors and vents NOT INTENDED FOR USE IN CRITICAL LIFE SUPPORT APPLICATIONS SAVE this Manual Provide thi...

Page 2: ...g Gasoline 9 2 8 Starting Pull Start Engines 10 2 9 Starting Electric Start Engines 10 2 10 Stopping the Engine 11 2 11 Low Oil Level Shutdown System 11 2 11 1 Sensing Low Oil Level 11 2 12 Charging t...

Page 3: ...definitions are as follows INDICATES A HAZARDOUS SITUATION OR ACTION WHICH IF NOT AVOIDED WILL RESULT IN DEATH OR SERIOUS INJURY Indicates a hazardous situation or action which if not avoided could re...

Page 4: ...frame and external electrically conductive parts of the generator be properly connected to an approved earth ground Local electrical codes may also require proper grounding of the generator Consult wi...

Page 5: ...rc org Rural Electricity Resource Council P O Box 309 Wilmington OH 45177 0309 5 ASAE EP 364 2 Installation and Maintenance of Farm Standby Electric Power available from www asabe org American Society...

Page 6: ...nd install the Frame Foot and Rubber Bumpers as shown Slide the Rubber Bumper studs through the Frame Foot then install the Locking Flange Nuts Slide the Hex Head Bolts through the holes in the Frame...

Page 7: ...to drain engine oil 5 Air Filter Filters intake air as it is drawn into the engine 6 Choke Knob Used when starting a cold engine 7 Fuel Tank See generator Specifications for tank capacity 8 Grounding...

Page 8: ...the meter is tracking hours of operation Figure 5 Hourmeter HOUR GLASS GRAPHIC RESET BUTTON IF EQUIPPED 0000 0 2 3 CORD SETS AND CONNECTION PLUGS 2 3 1 120 VAC 20 AMP DUPLEX RECEPTACLE This is a 120...

Page 9: ...RTABLE This generator has an equipment ground that connects the generator frame components to the ground terminals on the AC output receptacles see NEC 250 34 A for explanation This allows the generat...

Page 10: ...or does not give wattage multiply volts times ampere rating to determine watts volts x amps watts Some electric motors such as induction types require about three times more watts of power for startin...

Page 11: ...GASOLINE Never fill fuel tank indoors Never fill fuel tank when engine is running or hot Avoid spilling gasoline on a hot engine Allow engine to cool entirely before filling fuel tank DO NOT light a c...

Page 12: ...d repeat starting instructions IMPORTANT Do not overload the generator Also do not overload individual panel receptacles These outlets are protected against overload with push to reset type circuit br...

Page 13: ...hen the oil level drops below a specified level If the engine shuts down by itself and the fuel tank has enough gasoline check engine oil level 2 11 1 SENSING LOW OIL LEVEL If the system senses a low...

Page 14: ...31 inch or 0 70 0 80 mm Gasoline Capacity 25 6 Liters 6 77 U S gallons Oil Type See Chart in Before Starting the Generator Section Oil Capacity 1 Liters 1 06 Qts Run Time at 50 Load 10 Hours 7 5kW Dis...

Page 15: ...urns Allow engine to cool before draining oil Avoid prolonged or repeated skin exposure with used oil Thoroughly wash exposed areas with soap Use the following instructions to change the oil after the...

Page 16: ...leads to separation and formation of acids during storage Acidic gas can damage the fuel system of an engine while in storage To avoid engine problems the fuel system should be emptied before storage...

Page 17: ...9 Low oil level 10 Excessive rich fuel mixture 11 Intake valve stuck open or closed 12 Engine has lost compression 1 Turn Fuel Shut off ON 2 Clean or replace air filter 3 Fill fuel tank 4 Drain fuel...

Page 18: ...Manual Part No 0K0173 Rev B 01 24 13 Printed in China...

Page 19: ...Manual Parte No 0K0173 Rev B 24 01 13 Impreso en China...

Page 20: ...e combustible demasiado rica 11 V lvula de entrada atascada o cerrada 12 El motor ha perdido compresi n 1 Gire el cierre de combustible a ON 2 Limpie o reemplace el filtro de aire 3 Llene el tanque de...

Page 21: ...urante el almacenamiento Los gases cidos pueden da ar el sistema de combustible de un motor durante el almacenamiento Para evitar problemas con el motor el sistema de combustible deber vaciarse antes...

Page 22: ...ta que el motor enfr e antes de drenar el aceite Evite una exposici n prolongada o repetida de la piel con el aceite usado Lave completamente las reas expuestas con jab n Use las siguientes instruccio...

Page 23: ...84420101 Espaciamiento de la buj a 0 028 0 031 pulgadas o 0 70 0 80 mm Capacidad de gasolina 25 6 L 6 77 galones americanos Tipo de aceite Ver la cartilla en la secci n Antes de arrancar el generador...

Page 24: ...forma autom tica cuando el nivel de aceite cae por debajo de un nivel especificado Si el motor se apaga y el tanque de combustible tiene suficiente gasolina revise el nivel de aceite de motor 2 11 1 S...

Page 25: ...nerador Asimismo no sobrecargue los recept culos individuales Estas tomas est n protegidas contra sobrecargas con interruptores de circuito tipo presionar para reiniciar Si la corriente nominal de cua...

Page 26: ...motor est funcionando o est caliente Evite derramar gasolina sobre un motor caliente Deje enfriar al motor completamente antes de llenar el tanque de combustible NO encienda cigarrillos o fume cuando...

Page 27: ...es para determinar los vatios volts x amps vatios Algunos motores el ctricos como los del tipo inducci n requieren alrededor de tres veces m s potencia para arrancar que para funcionar Este transitori...

Page 28: ...odore NE JAMAIS utiliser la g n ratrice l int rieur d une r sidence ou d un garage M ME SI les portes et les fen tres sont ouvertes Utiliser uniquement L EXT RIEUR et loin des fen tres portes et vents...

Page 29: ...as horas de operaci n Figura 5 Hor metro GR FICO DE RELOJ DE ARENA BOT N DE REINICIO SI EST INSTALADO 0000 0 2 3 JUEGO DE CABLES Y CONECTORES 2 3 1 RECEPT CULO DUPLEX DE 120 VAC 20 AMP Esta es una tom...

Page 30: ...el fin de proteger al generador contra sobrecargas el ctricas 4 Drenaje de aceite Usar para drenar el aceite del motor 5 Filtro de aire Filtra el aire de ingreso al motor 6 Palanca de choke Se le usa...

Page 31: ...goma como se muestra Deslice los tacos del parachoques de goma a trav s de la pata del marco luego instale las contratuercas de cierre Deslice los pernos de cabeza hexagonal a trav s de los agujeros d...

Page 32: ...rerc org Consejo de Recursos de Electricidad Rural P O Box 309 Wilmington OH 45177 0309 5 ASAE EP 364 2 Instalaci n y mantenimiento de energ a el ctrica de respaldo en granjas disponible en www asabe...

Page 33: ...nas que son conductores el ctricos est n conectadas apropiadamente a una conexi n a tierra aprobada Los c digos el ctricos locales pueden asimismo requerir una apropiada conexi n a tierra del generado...

Page 34: ...TRAER COMO RESULTADO LA MUERTE O UN DA O SERIO ADVERTENCIA Indica una situaci n peligrosa o acci n que si no se evita podr a traer como resultado la muerte o un da o serio CUIDADO Indica una situaci n...

Page 35: ...Arranque de motores de recule 10 2 9 Arranque de motores con arranque el ctrico 10 2 10 Detener el Motor 11 2 11 Sistema de apagado por bajo nivel de aceite 11 2 11 1 Sensando el nivel de aceite 11 2...

Page 36: ...ARANT A LIMITADA DOS A OS DOS A OS PELIGRO HUMOS DE ESCAPE MORTALES Util celo SOLAMENTE al AIRE LIBRE y lejos de ventanas puertas y respiraderos NO DISE ADO PARA SER USADO EN APLICACIONES DE SOPORTE D...

Reviews: