SPECIFICATIONS

Maximum Surge Watts  . . . . . . . . . . . . . . . . .8,500 watts
Continuous Wattage Capacity  . . . . . . . . . . .5,500 watts
Power Factor  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.0
Rated Maximum Continuous AC Load Current:

At 120 Volts  . . . . . . . . . . . . . . . . . . . . . . .45.8 Amps
At 240 Volts  . . . . . . . . . . . . . . . . . . . . . . .22.9 Amps

Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1–phase
Rated Frequency  . . . . . . . . . . . . . . . . . . . . . . .60 Hertz
Fuel Tank Capacity . . . . . . . . . . . . . . . . . . . 5 U.S. gallons
Shipping Weight . . . . . . . . . . . . . . . . . . . . . . . . . 163 lbs.

GENERAL MAINTENANCE

RECOMMENDATIONS

The Owner/Operator is responsible for making sure that
all periodic maintenance tasks are completed on a timely
basis; that all discrepancies are corrected; and that the unit
is kept clean and properly stored. NEVER operate a
damaged or defective generator.

Engine Maintenance

See engine owner’s manual for instructions.

If you need service for your engine, you need to determine
the engine identification number.To do so, remove the
rocker arm cover hood, item number 55 shown on
page 16, by removing the four nuts and washers holding it
in place.The engine model-type-trim number is stamped on
the side of the inner cover attached to the engine. Have
this number in hand when you call the engine service
center for assistance.

CAUTION!

Avoid prolonged or repeated skin

contact with used motor oil. Used motor oil has
been shown to cause skin cancer in certain
laboratory animals.Thoroughly wash exposed areas
with soap and water.
KEEP OUT OF REACH OF CHILDREN. DON'T
POLLUTE. CONSERVE RESOURCES. RETURN
USED OIL TO COLLECTION CENTERS.

Generator Maintenance

Generator maintenance consists of keeping the unit clean
and dry. Operate and store the unit in a clean dry
environment where it will not be exposed to excessive
dust, dirt, moisture or any corrosive vapors. Cooling air
slots in the generator must not become clogged with snow,
leaves or any other foreign material.

NOTE: DO NOT use a garden hose to clean generator.
Water can enter engine fuel system and cause problems. In
addition, if water enters generator through cooling air slots,
some of the water will be retained in voids and cracks of
the rotor and stator winding insulation.Water and dirt
buildup on the generator internal windings will eventually
decrease the insulation resistance of these windings.

To Clean the Generator

CAUTION!

NEVER insert any object or tool

through the air cooling slots, even if the engine is
not running.

• Use a damp cloth to wipe exterior surfaces clean.

• A soft bristle brush may be used to loosen caked on dirt

or oil.

• A vacuum cleaner may be used to pick up loose dirt and

debris.

• Low pressure air (not to exceed 25 psi) may be used to

blow away dirt. Inspect cooling air slots and opening on
generator.These openings must be kept clean and
unobstructed.

Summary of Contents for 5500EXL

Page 1: ...Questions Help is just a moment away Call Generac Generator Helpline 1 800 270 1408 M F 8 5 CT Web www generac portables com or www briggsandstratton com Model No 1642 2 5 500 Watt AC Generator Manual...

Page 2: ...te of California a spark arrester is required by law Section 4442 of the California Public Resources Code Other states may have similar laws Federal laws apply on federal lands If you equip the muffle...

Page 3: ...jured Battery electrolyte fluid contains acid and is extremely caustic Contact with battery fluid will cause severe chemical burns DANGER DO NOT touch hot surfaces Allow equipment to cool before touch...

Page 4: ...lectrical overload Fuel Tank Capacity of five 5 U S gallons Grounding Wing Nut Used for proper grounding of unit see page 7 Oil Fill Add engine oil here Recoil starter Used to start the engine Rocker...

Page 5: ...carton Install Wheel Kit IMPORTANT This wheel kit is not intended for over the road use To install your wheel kit you need the following tools Two 13mm box open end or socket wrenches Install Wheel K...

Page 6: ...n for the life of the bearing Add Gasoline WARNING NEVER fill fuel tank indoors NEVER fill fuel tank when engine is running or hot Allow unit to cool for two minutes before refueling DO NOT light a ci...

Page 7: ...vary widely Consult with a local electrician for grounding requirements in your area Properly grounding the generator helps prevent electrical shock if a ground fault condition exists in the generato...

Page 8: ...R See Don t Overload the Generator on page 10 Stopping the Engine Unplug all electrical loads from generator panel receptacles NEVER start or stop engine with electrical devices plugged in and turned...

Page 9: ...ons temperatures below 40 F 4 C and a high dew point your generator may experience icing of the carburetor and or the crankcase breather system Build a structure that will enclose three sides and the...

Page 10: ...e generator output to stabilize engine runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilize 6 Repeat steps 4 and 5 for each...

Page 11: ...se skin cancer in certain laboratory animals Thoroughly wash exposed areas with soap and water KEEP OUT OF REACH OF CHILDREN DON T POLLUTE CONSERVE RESOURCES RETURN USED OIL TO COLLECTION CENTERS Gene...

Page 12: ...ator Let the unit cool for a sufficient time before placing the cover on the unit Engine Storage See engine owner s manual for instructions Other Storage Tips To prevent gum from forming in fuel syste...

Page 13: ...plug wire not connected to spark plug 7 Bad spark plug 8 Water in gasoline 9 Overchoking 10 Excessively rich fuel mixture 11 Intake valve stuck open or closed 12 Engine has lost compression 1 Set swit...

Page 14: ...14 PowerBoss 5 500 Watt Storm Plus Generator SCHEMATIC...

Page 15: ...PowerBoss 5 500 Watt Storm Plus Generator 15 WIRING DIAGRAM...

Page 16: ...16 PowerBoss 5 500 Watt Storm Plus Generator EXPLODED VIEW MAIN UNIT...

Page 17: ...831CGS 4 SCREW 41 80270GS 1 VALVE Tank 42 78299GS 1 BUSHING Plastic Tank 43 85134GS 1 CAP Fuel Gauge 44 189022GS 1 ASSY Tank Fuel Includes Items 41 42 Item Part Qty Description 45 189235GS 1 DECAL Sta...

Page 18: ...XPLODED VIEW AND PARTS LIST WHEEL KIT Item Part Qty Description 1 189715GS 1 ASSY Handle 2 B1764GS 1 LEG Mounting 3 52858GS 4 NUT Lock 4 39287GS 2 SCREW 5 191267HGS 1 AXLE 6 B4966GS 2 WHEEL 7 191265GS...

Page 19: ...pact 3 189167GS 2 CLIP Pin Retainer 4 189182GS 2 SPRING Hinge 5 189166GS 2 PIN Hinge 6 68759GS 2 OUTLET 120 V 20 A 7 189165GS 4 NUT Push 8 84198GS 2 CAP Circuit Breaker 9 75207GS 2 BREAKER Circuit 10...

Page 20: ...ER Mount 2 190032GS 1 ASSY ROTOR 3 190079AGS 1 ASSY STATOR 4 186060GS 1 RBC with O Ring p n 189197GS 5 86308HGS 4 SCREW 6 91825GS 1 ASSY Holder Rectifier Brush 7 66849GS 2 SCREW 8 22694GS 1 RECEPTACLE...

Page 21: ...PowerBoss 5 500 Watt Storm Plus Generator 21 NOTES...

Page 22: ...re Mantenga al menos 2 pies de espacio libre alrededor del generador para la adecuada ventilaci n NO opere el generador dentro de un edificio o lugar cerrado incluyendo el compartimiento del generador...

Page 23: ...electrolito de la bater a contiene cido y es extremadamente c ustico El contacto con el fluido de la bater a puede causar quemaduras qu micas severas PELIGRO NO toque las superficies calientes Permit...

Page 24: ...el motor y est equipado con una pantalla apagachispas Tanque del Combustible El tanque tiene una capacidad de 5 galones americanos de gasolina sin contenido de plomo Tomacorriente Dobles de 120 Voltio...

Page 25: ...el generador de la caja de env o Instale el Juego de Ruedas IMPORTANTE Este Juego de Ruedas no ha sido dise ado para ser usado en la carretera Para instalar su Juego de Ruedas usted necesitar las sig...

Page 26: ...combustible en recintos cerrados NUNCA llene el tanque del combustible cuando el motor est en funcionamiento o caliente NO encienda cigarrillos o fume cuando est llenando el tanque del combustible ADV...

Page 27: ...conocer los requisitos de conexi n a tierra de su rea La adecuada conexi n a tierra del generador ayuda a evitar descargas el ctricas si se produce alguna falla a tierra en el generador o en los disp...

Page 28: ...gina 30 Parado Del Motor Desconecte todas las cargas el ctricas de los tomaco rrientes del panel del generador NUNCA de arranque o detenga el motor con todos los dispositivos el ctricos conectados y e...

Page 29: ...o Dew su generador puede experimentar congelamiento del carburador y o el sistema de respiradero del cig e al Construya una estructura que pueda cubrir los tres lados y la parte superior del generador...

Page 30: ...mismo trabaja adecuadamente 4 Conecte y encienda la pr xima carga 5 De nuevo permita que el generador se estabilice 6 Repita los pasos 4 y 5 para cada carga adicional que usted tenga NUNCA a ada m s c...

Page 31: ...enerador consiste en conservar la unidad limpia y seca Opere y almacene la unidad en un ambiente limpio y seco donde no ser expuesta al polvo suciedad humedad o vapores corrosivos Las ranuras del aire...

Page 32: ...e coloque la cubierta Almacenando el Motor Consulte el manual del propietario del motor para las instrucciones de c mo preparar adecuadamente el motor para su almacenamiento Otras Sugerencias Para el...

Page 33: ...33 PowerBoss 5 500 Watt Storm Plus Generador NOTAS...

Page 34: ...Agua en la gasolina 8 Sobrecebado 9 Mezcla de combustible excesivamente rica 10 La v lvula de corte de combustible 11 La v lvula de entrada est atascada est cerrada 12 El motor ha perdido compresi n...

Page 35: ...ido autorizada o a cualquier tipo de alteraci n el mal uso negligencia accidentes sobrecarga velocidad excesiva mantenimiento inadecuado reparaci n o almacenamiento que seg n la opini n de los Product...

Page 36: ...en subjected to improper or unauthorized installation or alteration misuse negligence accident overloading overspeeding improper maintenance repair or storage so as in Generac Portable Products judgme...

Reviews: