Generac Power Systems 005974-0 Owner'S Manual Download Page 13

  

11

3.3 GENERAL RECOMMENDATIONS

The warranty of the generator does not cover items that have been 

subjected to operator abuse or negligence. To receive full value 

from the warranty, the operator must maintain the generator as 

instructed in this manual.
Some adjustments will need to be made periodically to properly 

maintain the generator.
All adjustments in the Maintenance section of this manual should 

be made at least once each season. Follow the requirements in the 

"Maintenance Schedule".

NOTE:

Once a year replace the spark plug and replace the air filter. 

A new spark plug and clean air filter assure proper fuel-air 

mixture and help the engine run better and last longer.

3.3.1 GENERATOR MAINTENANCE

Generator maintenance consists of keeping the unit clean and dry. 

Operate and store the unit in a clean dry environment where it will 

not be exposed to excessive dust, dirt, moisture or any corrosive 

vapors. Cooling air slots in the generator must not become 

clogged with snow, leaves, or any other foreign material.
Check the cleanliness of the generator frequently and clean when 

dust, dirt, oil, moisture or other foreign substances are visible on 

its exterior surface.



 

Never insert any object or tool through the air 

cooling slots, even if the engine is not running.

NOTE:

DO NOT use a garden hose to clean generator. Water can enter 

the engine fuel system and cause problems. In addition, if water 

enters the generator through cooling air slots, some water will 

be retained in voids and crevices of the rotor and stator winding 

insulation. Water and dirt buildup on the generator internal 

windings will eventually decrease the insulation resistance of 

these windings.

3.3.2  TO CLEAN THE GENERATOR

•  Use a damp cloth to wipe exterior surfaces clean.

•  A soft, bristle brush may be used to loosen caked on dirt, oil, 

etc.

• A vacuum cleaner may be used to pick up loose dirt and 

debris.

• Low pressure air (not to exceed 25 psi) may be used to 

blow away dirt. Inspect cooling air slots and openings 

on the generator. These openings must be kept clean and 

unobstructed.

3.3.3 ENGINE MAINTENANCE



 When working on the generator, always 

disconnect spark plug wire from spark plug and 

keep wire away from spark plug.

3.3.4  CHECKING OIL LEVEL

See the “Before Starting the Generator” section for information on 

checking the oil level. The oil level should be checked before each 

use, or at least every eight hours of operation. Keep the oil level 

maintained.

3.3.5 CHANGING THE OIL

Change the oil after every 100 hours. If running this unit under 

dirty or dusty conditions, or in extremely hot weather, change the 

oil more often.



 

Hot oil may cause burns. Allow engine to 

cool before draining oil. Avoid prolonged 

or repeated skin exposure with used oil. 

Thoroughly wash exposed areas with soap.

Use the following instructions to change the oil after the engine 

cools down:

•  Clean area around oil drain plug.
•  Remove oil drain plug from engine and oil fill plug to drain oil 

completely into a suitable container.

• When oil has completely drained, install oil drain plug and 

tighten securely.

• Fill engine with recommended oil. (See “Before Starting the 

Generator” for oil recommendations).

•  Wipe up any spilled oil.
•  Dispose of used oil at a proper collection center.

3.3.6  REPLACING THE SPARK PLUG

Use Champion N9YC spark plug or equivalent. 

Replace the plug 

once each year.

 This will help the engine start easier and run 

better.

1.  Stop the engine and pull the spark plug wire off of the spark 

plug.

2.  Clean the area around the spark plug and remove it from the 

cylinder head.

3.  Set the spark plug's gap to 0.70-0.80 mm (0.028-0.031 in.). 

Install the correctly gapped spark plug into the cylinder head 

(Figure 12).

Figure 12 - Spark Plug Gap

Maintenance

Summary of Contents for 005974-0

Page 1: ...P Series Portable Generator MODELS 005974 0 005975 0 005976 0 DEADLY EXHAUST FUMES ONLY use OUTSIDE far away from windows doors and vents NOT INTENDED FOR USE IN CRITICAL LIFE SUPPORT APPLICATIONS SAV...

Page 2: ...Adding Gasoline 8 2 8 Starting Pull Start Engines 9 2 9 Stopping the Engine 10 2 10 Low Oil Level Shutdown System 10 2 10 1 Sensing Low Oil Level 10 Maintenance 10 3 1 Maintenance Schedule 10 3 2 Prod...

Page 3: ...DOUS SITUATION OR ACTION WHICH IF NOT AVOIDED WILL RESULT IN DEATH OR SERIOUS INJURY Indicates a hazardous situation or action which if not avoided could result in death or serious injury Indicates a...

Page 4: ...or while hands or feet are wet DANGEROUS ELECTRICAL SHOCK MAY RESULT The National Electric Code NEC requires the frame and external electrically conductive parts of the generator be properly connecte...

Page 5: ...2 Article X NATIONAL BUILDING CODE available from the American Insurance Association 85 John Street New York N Y 10038 3 AGRICULTURAL WIRING HANDBOOK available from the Food and Energy Council 909 Un...

Page 6: ...he Hex Head Bolts then install the Locking Flange Nuts 3 Refer to Figure 1 and install the Handle as shown Slide the long Bolts through the Handle Bracket and Handle then install the Hex Nuts Figure 1...

Page 7: ...e service Every 200 hours the SVC icon on the lower left hand corner of the display will flash The message will flash one hour before and one hour after each 200 hour interval providing a two hour win...

Page 8: ...0 watts 7 2 kW of power at 30 Amps The outlet is protected by two 25 Amp 5 0 5 5kW or two 30 Amp 6 5kW push to reset circuit breakers Figure 6 120 240 VAC 30 Amp Receptacle 2 4 HOW TO USE THE GENERATO...

Page 9: ...rical shock However local codes may vary widely Consult with a local electrician for grounding requirements in the area Proper grounding of the generator will help prevent electrical shock in the even...

Page 10: ...ARTING THE GENERATOR Prior to operating the generator engine oil and gasoline will need to be added as follows 2 7 1 ADDING ENGINE OIL All oil should meet minimum American Petroleum Institute API Serv...

Page 11: ...30 days or longer See the Storage section Never use engine or carburetor cleaner products in the fuel tank as permanent damage may occur 2 8 STARTING PULL START ENGINES Never start or stop engine with...

Page 12: ...ey cannot be adequately cleaned Check valve clearance and adjust if necessary after first 50 hours of operation and every 100 hours thereafter 3 2 PRODUCT SPECIFICATIONS 3 2 1 GENERATOR SPECIFICATIONS...

Page 13: ...soft bristle brush may be used to loosen caked on dirt oil etc A vacuum cleaner may be used to pick up loose dirt and debris Low pressure air not to exceed 25 psi may be used to blow away dirt Inspec...

Page 14: ...stem parts such as the carburetor fuel hose or tank during storage Also experience indicates that alcohol blended fuels called gasohol ethanol or methanol can attract moisture which leads to separatio...

Page 15: ...9 Low oil level 10 Excessive rich fuel mixture 11 Intake valve stuck open or closed 12 Engine has lost compression 1 Turn Fuel Shut off ON 2 Clean or replace air filter 3 Fill fuel tank 4 Drain fuel...

Page 16: ...14 Notes...

Page 17: ...15 Notes...

Page 18: ...on as a problem occurs The warranty repairs should be completed in a reasonable amount of time not to exceed 30 days Warranty service can be arranged by contacting either your selling dealer or a Gene...

Page 19: ...int for that part If the part fails prior to the first scheduled replacement the part shall be repaired or replaced by Generac according to Subsection 4 below Any such emissions related part repaired...

Page 20: ...choose to Repair Replace or Refund a piece of equipment 5 Warranty Labor Rates are based on normal working hours Additional costs for overtime holiday or emergency labor costs for repairs outside of n...

Page 21: ...DELOS 005974 0 005975 0 005976 0 2A OS GARANT A LIMITADA PELIGRO HUMOS DE ESCAPE MORTALES Util celo SOLAMENTE al AIRE LIBRE y lejos de ventanas puertas y respiraderos NO DISE ADO PARA SER USADO EN APL...

Page 22: ...ar gasolina 28 2 8 Arranque de motores de arranque por tiro 29 2 9 Deteniendo el Motor 30 2 10 Sistema de apagado por bajo nivel de aceite 30 2 10 1 Sensando el nivel de aceite 30 Mantenimiento 30 3 1...

Page 23: ...PELIGRO INDICA UNA SITUACI N PELIGROSA O ACCI N QUE SI NO SE EVITA TRAER COMO RESULTADO LA MUERTE O UN DA O SERIO ADVERTENCIA Indica una situaci n peligrosa o acci n que si no se evita podr a traer co...

Page 24: ...ctrico ni dispositivo mientras est de pie sobre agua con los pies descalzos o con las manos o pies h medos PUEDE HABER UNA DESCARGA EL CTRICA COMO RESULTADO El C digo El ctrico Nacional NEC requiere...

Page 25: ...ATIONAL BUILDING CODE disponible en la American Insurance Association 85 John Street New York N Y 10038 3 AGRICULTURAL WIRING HANDBOOK disponible en la Food and Energy Council 909 University Avenue Co...

Page 26: ...del soporte del manubrio y del manubrio y luego instale los pernos hexagonales Figura 1 Ensamble de la rueda y el manubrio TUERCA BELLOTA M8 UNIDAD DE MANUBRIO RUEDA X 2 PATA DEL MARCO PATA DE GOMA X...

Page 27: ...ras el icono SVC en la esquina inferior izquierda de la pantalla destellar El mensaje destellar una hora antes y una hora despu s de cada intervalo de 200 horas proporcionando una ventana de dos horas...

Page 28: ...ecept culo de 120 240 VAC 30 Amp Use este recept culo para operar cargas monof sicas de 120 Voltios AC a 60 Hz que requieran hasta 3600 vatios 3 6 Kw de potencia a 30 amperios o 240 VAC 60 hz monof si...

Page 29: ...a de bronce o cobre de tierra electrodo proporciona una protecci n adecuada contra descargas el ctricas Sin embargo los c digos locales pueden variar ampliamente Consulte con un electricista local los...

Page 30: ...ceite de motor y gasolina de esta manera 2 7 1 AGREGAR ACEITE DE MOTOR Todo aceite debe cumplir el est ndar m nimo de la American Petroleum Institute API Service Class SJ SL o superior No use aditivos...

Page 31: ...amiento Nunca use productos limpiadores de motor o carburador en el tanque de combustible ya que puede ocasionar da o permanente 2 8 ARRANQUE DE MOTORES DE RECULE ADVERTENCIA Nunca arranque ni detenga...

Page 32: ...s como contenido en BTUs del combustible altitud condiciones del motor etc La potencia m xima disminuye alrededor del 3 5 por cada 1000 pies sobre el nivel del mar y tambi n disminuir alrededor del 1...

Page 33: ...de drenar el aceite Evite una exposici n prolongada o repetida de la piel con el aceite usado Lave completamente las reas expuestas con jab n Use las siguientes instrucciones para cambiar el aceite lu...

Page 34: ...durante el almacenamiento Para evitar problemas con el motor el sistema de combustible deber vaciarse antes de almacenarse por 30 d as o m s como sigue Retire toda la gasolina del tanque de combustibl...

Page 35: ...a de combustible demasiado rica 11 V lvula de entrada atascada o cerrada 12 El motor ha perdido compresi n 1 Gire el cierre de combustible a ON 2 Limpie o reemplace el filtro de aire 3 Llene el tanque...

Page 36: ...garant a de Generac tan pronto se presente el problema Las reparaciones de garant a deber n completarse en un tiempo razonable sin exceder los 30 d as El servicio de garant a puede arreglarse contact...

Page 37: ...reemplazo programado la parte ser reparada o reemplazada por Generac de acuerdo a la Subsecci n 4 m s abajo Cualquier parte relacionada a las emisiones as reparada o reemplazada bajo la garant a ECS s...

Page 38: ...ar o reembolsar un equipo 5 Los costos de mano de obra cubiertos por garant a se basan en horas normales de trabajo Costos adicionales por sobretiempos feriados o trabajos de emergencia fuera de horas...

Page 39: ...OD LES 005974 0 005975 0 005976 0 GARANTIE LIMIT E DE 2 ANS 2 ANS GAZ D CHAPPEMENT MORTEL Utiliser UNIQUEMENT L EXT RIEUR loin des fen tres portes et vents L UTILISATION N EST PAS PR VUE POUR LES MOYE...

Page 40: ...essence 46 2 8 D marrage des moteurs d marrage manuel 47 2 9 Arr t du moteur 48 2 10 Syst me d arr t de bas niveau d huile 48 2 10 1 D tection de bas niveau d huile 48 Maintenance 48 3 1 Programme de...

Page 41: ...une situation ou une action dangereuse qui si elle n est pas vit e pourrait entra ner la mort ou des blessures graves ATTENTION Indique une situation ou une action dangereuse qui si elle n est pas vi...

Page 42: ...al exige que le b ti et que les pi ces externes lectriquement conductrices du g n rateur soient correctement reli s une terre approuv e Les codes lectriques locaux peuvent galement exiger la bonne mis...

Page 43: ...bia MO 65201 4 ASAE EP 3634 INSTALLATION AND MAINTENANCE OF FARM STANDBY ELECTRICAL SYSTEMS Installation et maintenance des syst mes lectriques de secours pour les fermes disponible aupr s de l Americ...

Page 44: ...rter au Sch ma 1 et installer la poign e comme indiqu Faire glisser les boulons longs travers le support de poign e et la poign e puis installer les crous hexagonaux Sch ma 1 Roue et poign e CROU BORG...

Page 45: ...situ e en bas gauche de l cran clignotera Le message clignotera une heure avant et une heure apr s chaque intervalle de 200 heures laissant une marge de deux heures pour effectuer l entretien Lorsque...

Page 46: ...e 25 A 5 5 5 kW ou deux disjoncteurs de 30 A 6 5 kW Sch ma 6 Prise 120 240 V C A 30 A 2 4 UTILISATION DU G N RATEUR Si des probl mes se pr sentent lors du fonctionnement du g n rateur merci d appeler...

Page 47: ...des fils la borne de mise la terre et une tige en cuivre conduite la terre ou une tige la terre lectrode en laiton fournit une protection appropri e contre les lectrocutions Cependant les codes locau...

Page 48: ...e API Institut am ricain du p trole N utiliser aucun additif sp cial S lectionner le degr de viscosit d huile selon la temp rature d exploitation se reporter galement au tableau Au dessus de 40 F util...

Page 49: ...produit nettoyant pour moteur ou carburateur dans le r servoir d essence tant donn que cela pourrait causer des dommages permanents 2 8 D MARRAGE DES MOTEURS D MARRAGE MANUEL AVERTISSEMENT Ne jamais...

Page 50: ...sance nominale 5 5 5 6 5 kW Puissance de surtension 6 25 6 88 8 kW Tension c a nominale 120 240 Charge c a nominale Courant 240 V 5 5 5 6 5 kW 20 8 22 9 27 1 A Courant 120 V 5 5 5 6 5 kW 41 6 45 8 54...

Page 51: ...au minimum toutes les huit heures de fonctionnement Il est n cessaire de conserver un certain niveau d huile 3 3 5 CHANGEMENT DE L HUILE Changer l huile toutes les 100 heures Changer l huile plus sou...

Page 52: ...iter tout probl me avec le moteur le circuit de carburant doit tre vid avant le stockage du moteur si celui ci est d au moins 30 jours Pour cela Vidanger le r servoir d essence de tout le carburant qu...

Page 53: ...osition ouverte ou ferm e 12 Perte de compression du moteur 1 Mettre la soupape d arr t sur ON Marche 2 Nettoyer ou remplacer le filtre air 3 Remplir le r servoir d essence 4 Vidanger le r servoir d e...

Page 54: ...aine n ayant pas t fabriqu es fournies ou approuv es par Generac Vous tes charg de contacter un d positaire de garantie agr par Generac d s qu un probl me se pr sente Les r parations effectu es dans l...

Page 55: ...ement pr vu elle sera r par e ou remplac e par Generac conform ment au paragraphe 4 qui suit Ces pi ces relatives aux missions r par es ou remplac es dans le cadre de la Garantie du SCE seront garanti...

Page 56: ...ipement 5 Le taux de main d uvre sous garantie est bas sur les heures normales de travail Les autres frais relatifs aux heures suppl mentaires aux vacances ou aux co ts salariaux pour les r parations...

Reviews: