Generac Portable Products 2,500 PSI High Pressure Washer
14
Check In-Line Filter
Refer to Figure 17 and service the in-line filter if it
becomes clogged, as follows:
1.
Detach spray gun and nozzle extension from high
pressure hose. Detach nozzle extension from spray
gun and remove o-ring and screen from nozzle
extension. Flush the screen, spray gun, and nozzle
extension with clean water to clear debris.
2.
If the screen is damaged, the o-ring kit contains a
replacement in-line filter screen and an o-ring. If
undamaged, reuse screen.
3.
Place the in-line filter screen into the threaded end of
the nozzle extension. Direction does not matter. Push
the screen in with the eraser end of a pencil until it
rests flat at the bottom of the opening. Take care to
not bend the screen.
4.
Place the o-ring into the recess. Push the o-ring snugly
against the in-line filter screen.
5.
Assemble the nozzle extension to the spray gun, as
described earlier in this manual.
Check Spray Gun and Nozzle
Extension
Examine the hose connection to the spray gun and make
sure it is secure. Test the trigger by pressing it and making
sure it springs back into place when you release it. Put the
safety latch in the ON position and test the trigger. You
should not be able to press the trigger.
Purge Pump of Air and
Contaminants
To remove air from the pump, follow these steps:
• Set up the pressure washer as described in “Preparing
the Pressure Washer for Use” and connect the water
supply. Turn ON the water.
• Pull the trigger on the spray gun and hold.
• When the water supply is steady and constant, engage
the safety latch.
To remove contaminants from the pump, follow
these steps:
• Set up the pressure washer as described in “Preparing
the Pressure Washer for Use” and connect the water
supply.
• Remove the nozzle extension from the spray gun.
• Start the engine according to instructions given in “How
To Use Your Pressure Washer”.
• Squeeze the trigger on the spray gun and hold.
• When the water supply is steady and constant, engage
the safety latch and refasten the nozzle extension.
Detergent Siphon Tube
If you have used the detergent siphon tube you must flush
it with clean water before storing the unit.
• Place the detergent siphon tube in a bucket full of clean
water.
• With the engine running, flush for 1–2 minutes.
• Shut off the engine.
IMPORTANT:
Simply shutting OFF engine will not
release pressure in the system. When the engine has shut
down, squeeze the trigger on the spray gun to
relieve the pressure in the hose.
Figure 17 — Clean In-Line Filter
Nozzle Extension
Filter Screen
O-ring
Summary of Contents for 1443-0
Page 18: ...Generac Portable Products 2 500 PSI High Pressure Washer 18 NOTES...
Page 19: ...Generac Portable Products 2 500 PSI High Pressure Washer 19 SCHEMATIC AND WIRING DIAGRAM...
Page 20: ...Generac Portable Products 2 500 PSI High Pressure Washer 20 EXPLODED VIEW UNIT...
Page 22: ...Generac Portable Products 2 500 PSI High Pressure Washer 22 EXPLODED VIEW PUMP...