background image

4 English

Settings and Acoustic 

Calibration

The Smart Active Monitors are extremely flexible 
in compensating the acoustic influences of the 
room and support automated setup using the GLM 
User Kit and software. The 8320A and 8330A are 
compatible with GLM 2.0 and later.

The GLM software can be downloaded from 

Genelec web site (www.genelec.com/glm). The 
GLM 2.0 User Kit is needed for the setup. The 
User Kit contains the GLM Adapter and GLM 
measurement microphone.  

The GLM Adapter is connected to the computer 

USB port and the GLM network. The GLM 
measurement microphone is placed at the listening 
location. 

Execute the setup process in the GLM software 

to align and set up the Smart Active Monitors and 
Subwoofers as a system. After calibration, keep 
the computer connected to maintain the settings 
or save the settings to the Smart Active Monitors 
using the GLM software.

ISS

TM

 Autostart Function

Intelligent Signal Sensing

TM

 (ISS

TM

) enables very low 

standby power consumption, less than 0.5 watts. 

As a factory default, the ISS function is disabled. 

The ISS function can be enabled by clicking the 
“ISS Power Saving” pulldown menu in the GLM 
software. This menu also provides a selection of 
the time before entering standby. The playback 
resumes once an input signal is detected. There is 
a slight delay before playback resumes.

Mounting Considerations

Align the Monitors Correctly
Place and point the monitors so that their acoustic 

axes (see figure 1) are aimed towards the listening 
position. Vertical orientation is preferred, as this 
minimises the sound colour change around the 
crossover frequency when the listener is moving 
horizontally.

Maintain Symmetry
Place the monitors at an equal distance from the 
listening position and symmetrically relative to the 
room walls. Place the listening position on the room 
front-back centreline and the monitors at an equal 
distance from this centreline.

Minimise Reflections
Acoustic reflections are created by objects close to 
the monitors. Such objects can be desks, cabinets, 
computer monitors etc. Acoustic reflections can 
cause unwanted sound colouration and sound 
image instability. These can be minimised by 
placing the monitors and the listening position 
clear of reflective surfaces. 

Minimum Clearances

Sufficient clearance for amplifier cooling and reflex 
port function must be ensured. The surroundings 
of the monitor must be open to the listening room 
with a minimum clearance of 3 centimeters (1

3

/

16

 in) 

behind, above, and on both sides of the monitor. 
The ambient temperature may not rise above 35 
degrees Celsius (95°F.) 

Mounting Options

The Genelec 8320A and 8330A offer several 
mounting options:  The Iso-Pod™ (Isolation 
Positioner/Decoupler™) vibration insulating stand 
allows tilting of the monitor to correctly align 
the acoustic axis. The bottom of the monitor has 

Summary of Contents for SAM 8320A

Page 1: ...8320A 8330A Operating Manual ...

Page 2: ... acoustic neutrality Delivery Contents Each monitor is supplied with a mains cable 5 meter RJ45 cable and an operating manual Connections Before connecting switch off the monitors and the signal source Once all the connections have been made the monitors can be switched on Mains Power The power switch is located on the back panel see Figure 2 Connect the monitor to a mains socket having a protecti...

Page 3: ... information MAINS INPUT 50 60 Hz 60 W 100 240 V GLM NETWORK SMART ACTIVE MONITOR 292 8030W RISQUE DE CHOC ÉLECTRIQUE NE PAS DIGITAL IN 292 8330T 6 ANALOG IN DIGITAL OUT GND 2 3 1 1 2 3 GND IN OUT GLM NETWORK CONNECTORS MAINS INPUT POWER SWITCH SIGNAL CONNECTORS DIGITAL IN DIGITAL OUT ANALOG IN Figure 3 GLM Network Adapter cabling Audio cabling is not shown LISTENING POSITION MICROPHONE GLM NETWOR...

Page 4: ... playback resumes Mounting Considerations Align the Monitors Correctly Place and point the monitors so that their acoustic axes see figure 1 are aimed towards the listening position Vertical orientation is preferred as this minimises the sound colour change around the crossover frequency when the listener is moving horizontally Maintain Symmetry Place the monitors at an equal distance from the lis...

Page 5: ...nteed for a period of two years against faults in materials or workmanship Refer to supplier for full sales and guarantee terms Compliance to FCC Rules This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions This device may not cause harmful interference and this device must accept any interference received including interference that may cause undes...

Page 6: ...6 English Figure 4 Horizontal and vertical directivity plots of the 8320A and 8330A ...

Page 7: ...metal dome Weight 3 2 kg 7 0 lb 5 5 kg 12 1 lb Dimensions Height including Iso Pod table stand Height without Iso Pod table stand Width Depth 242 mm 91 2 in 230 mm 91 16 in 151 mm 6 in 142 mm 55 8 in 299 mm 1113 16 in 285 mm 111 4 in 189 mm 77 16 in 178 mm 7 in Bass amplifier short term output power Treble amplifier short term output power 50 W 50 W Total harmonic distortion at nominal output 0 05...

Page 8: ... genelec com In China Beijing Genelec Audio Co Ltd Room 101 1st floor Building 71 B33 Universal Business Park No 10 Jiuxianqiao Road Chaoyang District Beijing China Phone 86 10 5823 2014 Post code 100015 Email genelec china genelec com Figure 5 Frequency response plots in horizontal plane of the 8320A and 8330A The lower curve is the monitor s power response 20 20k 50 100 200 500 1k 2k 5k 10k Hz G...

Reviews: