background image

2 English

Figure 1: Location of the acoustic axis

General Description

Genelec 8320A and 8330A are two-way smart 
active monitors designed for demanding 
professional applications. 

Genelec Smart Active Monitor™ (SAM™) 

digital signal processing (DSP) built inside each 
smart active monitor with Genelec Loudspeaker 
Manager™ (GLM™) software provides 
unparalleled acoustic quality, ease of use, and 
high monitoring accuracy even in difficult acoustic 
environments. The high performance drivers are 
directly connected to dedicated D Class power 
amplifiers. System protection is implemented as 
a part of the SAM signal processing.

The MDE™ (Minimum Diffraction Enclosure™) 

enclosure is made of die-cast aluminium and 
shaped to reduce edge diffraction. Combined 
with the advanced Directivity Control Waveguide

TM

 

(DCW

TM

), this design contributes to the excellent 

acoustic neutrality.

Delivery Contents

Each monitor is supplied with a mains cable, 5 
meter RJ45 cable, and an operating manual. 

Connections

Before connecting, switch off the monitors and the 
signal source. Once all the connections have been 
made, the monitors can be switched on.

Mains Power
The power switch is located on the back panel (see 
Figure 2). Connect the monitor to a mains socket 
having a protective earthed connection. Do not 
connect to an unearthed mains supply or using an 
unearthed mains cable. These monitors feature an 
universal mains voltage and can be connected to 
any voltage between 100-240 VAC 50-60 Hz.

GLM Network Connection
Up to 30 monitors and subwoofers can be 
connected to a computer using the GLM Adapter. 
An RJ45 cable is supplied for this. Start control 
network cabling from the GLM Adapter to the first 
monitor. Continue daisy-chaining to all monitors 
and subwoofers (see Figure 3). No special 
sequence is necessary. 

8320A and 8330A

 

         Operating Manual

> 0,7

m

ACOUSTIC

AXIS

H

H

8320 146 mm 5

3

/

4

 in

8330 190 mm 7

1

/

2

 in

Summary of Contents for SAM 8320A

Page 1: ...8320A 8330A Operating Manual ...

Page 2: ... acoustic neutrality Delivery Contents Each monitor is supplied with a mains cable 5 meter RJ45 cable and an operating manual Connections Before connecting switch off the monitors and the signal source Once all the connections have been made the monitors can be switched on Mains Power The power switch is located on the back panel see Figure 2 Connect the monitor to a mains socket having a protecti...

Page 3: ... information MAINS INPUT 50 60 Hz 60 W 100 240 V GLM NETWORK SMART ACTIVE MONITOR 292 8030W RISQUE DE CHOC ÉLECTRIQUE NE PAS DIGITAL IN 292 8330T 6 ANALOG IN DIGITAL OUT GND 2 3 1 1 2 3 GND IN OUT GLM NETWORK CONNECTORS MAINS INPUT POWER SWITCH SIGNAL CONNECTORS DIGITAL IN DIGITAL OUT ANALOG IN Figure 3 GLM Network Adapter cabling Audio cabling is not shown LISTENING POSITION MICROPHONE GLM NETWOR...

Page 4: ... playback resumes Mounting Considerations Align the Monitors Correctly Place and point the monitors so that their acoustic axes see figure 1 are aimed towards the listening position Vertical orientation is preferred as this minimises the sound colour change around the crossover frequency when the listener is moving horizontally Maintain Symmetry Place the monitors at an equal distance from the lis...

Page 5: ...nteed for a period of two years against faults in materials or workmanship Refer to supplier for full sales and guarantee terms Compliance to FCC Rules This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions This device may not cause harmful interference and this device must accept any interference received including interference that may cause undes...

Page 6: ...6 English Figure 4 Horizontal and vertical directivity plots of the 8320A and 8330A ...

Page 7: ...metal dome Weight 3 2 kg 7 0 lb 5 5 kg 12 1 lb Dimensions Height including Iso Pod table stand Height without Iso Pod table stand Width Depth 242 mm 91 2 in 230 mm 91 16 in 151 mm 6 in 142 mm 55 8 in 299 mm 1113 16 in 285 mm 111 4 in 189 mm 77 16 in 178 mm 7 in Bass amplifier short term output power Treble amplifier short term output power 50 W 50 W Total harmonic distortion at nominal output 0 05...

Page 8: ... genelec com In China Beijing Genelec Audio Co Ltd Room 101 1st floor Building 71 B33 Universal Business Park No 10 Jiuxianqiao Road Chaoyang District Beijing China Phone 86 10 5823 2014 Post code 100015 Email genelec china genelec com Figure 5 Frequency response plots in horizontal plane of the 8320A and 8330A The lower curve is the monitor s power response 20 20k 50 100 200 500 1k 2k 5k 10k Hz G...