USE
-
To activate the keypad press any key for 3 seconds, then you can view and change the set point, if necessary;
press the
key just once to display the set temperature, which can be changed using the up and down
arrow keys by pressing and holding for 3 sec the same key.
-
With the keypad active, a manual defrost can be selected; press and hold for 3 sec the
key and if the
evaporator temperature is no higher than +8°C, a manual defrost phase is activated. This phase ends either
when the time o
f 20’ has elapsed or when the temperature measured by the evaporator sensor is (+8°C). The
automatic defrost, managed by the controller, takes place once every 12H for a max. of 20’ during which time
the readout dEF is shown on the display.
-
With the keypad active, press keys
and
just once to display the maximum and minimum
temperature respectively, which are recorded by the sensor inside the cabinet. The displayed values are
preceded by the readouts LO and HY respectively. To reset this stored value, press and hold for 3sec the
key at the time it is displayed. On the display this reset is preceded by the readout RST (reset).
7.7.1
–
SPECIAL USE
-
With the keypad active, press and hold for 3 sec the
key to activate the CONTINUOUS CYCLE phase.
This phase lasts (1H) at a temperature (+4°C). These values are factory set in the controller. Unlike the normal
refrigerating phase, in this case the symbol
on the display is lit. When the set time (1H) has elapsed, the
symbol will go out and the appliance will start once again to operate with the previous set point.
7.7.2
–
STOPPING FOR LONG PERIODS
With the appliance OFF and the keypad active, press the
key and pull the plug out of the socket.
Thoroughly clean the appliance (as described under 8.2) and make sure the door is left ajar at the end of cleaning and
remains ajar for the entire period that the appliance is not used.
Summary of Contents for BRERA Series
Page 2: ...WL5 1 2 Rev 00 05 2013 pag 2...
Page 7: ...WL5 1 2 Rev 00 05 2013 pag 7 1 2 DICHIARAZIONE DI CONFORMITA...
Page 35: ...WL5 1 2 Rev 00 05 2013 pag 35 1 2 DECLARATION OF CONFORMITY 1 3 WARRANTY...
Page 63: ...WL5 1 2 Rev 00 05 2013 pag 63 1 2 KONFORMIT TSERKL RUNG...
Page 91: ...WL5 1 2 Rev 00 05 2013 pag 91 1 2 D CLARATION DE CONFORMIT...
Page 118: ...WL5 1 2 Rev 00 05 2013 pag 118...
Page 119: ...WL5 1 2 Rev 00 05 2013 pag 119...
Page 120: ...WL5 1 2 Rev 00 05 2013 pag 120...
Page 121: ...WL5 1 2 Rev 00 05 2013 pag 121...