CLEANING THE APPLIANCE CONDENSER
The condenser must be cleaned once every 60 days.
APPLIANCE STATUS:
-
ON/OFF button on OFF (
on the display);
-
power supply plug disconnected from the mains.
AUTHORIZED PERSONNEL
Appliance operator.
METHOD
For trouble-free efficient appliance operation, the air-cooled condenser (ref. 1 fig. 10) must be kept clean so that air
circulates freely. Cleaning must be done once every 60 days at the most. Remove the control panel having first removed
the top screws (ref. 2 fig. 10) and released the bottom pins. Use non-metallic brushes to clean, ensuring that all the dust
and fluff is removed from the fins. We recommend using a vacuum cleaner so as to avoid dust being spread into the
environment. If there are greasy deposits, remove them using a small brush soaked in alcohol.
DO NOT SCRAPE THE
SURFACES WITH SHARP POINTED OR ABRASIVE OBJECTS.
Fig. 10
The condenser has sharp edges. When carrying out the operations mentioned above, wear safety
gloves, goggles and face masks.
Do not use direct water jets to clean the appliance.
Summary of Contents for BRERA Series
Page 2: ...WL5 1 2 Rev 00 05 2013 pag 2...
Page 7: ...WL5 1 2 Rev 00 05 2013 pag 7 1 2 DICHIARAZIONE DI CONFORMITA...
Page 35: ...WL5 1 2 Rev 00 05 2013 pag 35 1 2 DECLARATION OF CONFORMITY 1 3 WARRANTY...
Page 63: ...WL5 1 2 Rev 00 05 2013 pag 63 1 2 KONFORMIT TSERKL RUNG...
Page 91: ...WL5 1 2 Rev 00 05 2013 pag 91 1 2 D CLARATION DE CONFORMIT...
Page 118: ...WL5 1 2 Rev 00 05 2013 pag 118...
Page 119: ...WL5 1 2 Rev 00 05 2013 pag 119...
Page 120: ...WL5 1 2 Rev 00 05 2013 pag 120...
Page 121: ...WL5 1 2 Rev 00 05 2013 pag 121...