We reserve the right to modify the characteristics of the equipment supplied without notice or as part of the continued development of our products. 

 
 

              2 

 ELECTRICAL CONNECTIONS 

FOR EBS RANGE OF CYLINDERS 

 

 

Please Note 

 
The Electrical “Straight Line” wiring diagram supplied with this literature is intended to assist in the 
understanding of how the system works for fault finding and general assistance on the EBS cylinder, it 
has no knowledge of individual peripherals fitted to the beginning or the end of the line, it does not 
provide information on your chosen peripherals. Please refer to the manufacturer’s literature supplied 
with each item you choose to install or please contact the Geminox-UK Technical helpline for further 
assistance on + 44 (0)1372 722277. 
 

Index 
Page 

 

2 Index 

WRc approved documentation *

Contains important information, please read* 

*Important notice, please read* 

Hydraulic connections for cylinders 

Cylinders with immersion heaters 

11 

Cylinders without immersion heaters 

 

 

Figures 

 

Fig  1                              ¾” Unvented kit for EBS cylinder 

 

 

 

Fig  2                              ¾” Unvented kit for EBS cylinder 

Fig  3                               1” Unvented kit for EBS cylinder 

Fig  4                               1” Unvented kit for EBS cylinder 

10 

Fig  5                                ¾” Safety zone valve 

10 

Fig  6                                1”  Safety zone valve 

13 

Fig  7                                Requirements for EBS domestic unvented hot water cylinder 

14 

Fig  8                                EBS cylinder sensor 

15 

Fig  9                                Cylinder with immersion heater 

16 

Fig  10                              Cylinder without immersion heater 

17 

Fig  11       

 

  Heating immersion set 

18 

Fig  12                              Discharge pipe arrangement using Hepworth Hep vO valve 

 

Please ensure that prior to starting any Electrical work the cylinder has been isolated from the 
mains supply.  Where possible, lock off and warning signs to be posted.  
Only Qualified Electricians should carry out the work necessary.

Summary of Contents for EBS 100

Page 1: ...We reserve the right to modify the characteristics of the equipment supplied without notice or as part of the continued development of our products 0...

Page 2: ...100 313 531 THI 0 9 9 C BS 300 9 1 4 4 37 7 86 153 476 693 THI 2 13 C BS 100 13 5 6 5 15 2 19 35 160 483 THI 2 13 C BS 150 13 5 6 5 21 3 29 52 241 564 THI 2 13 C BS 200 13 5 6 5 26 7 38 68 313 636 TH...

Page 3: ...ex Page 2 Index 3 WRc approved documentation Contains important information please read 6 Important notice please read 7 Hydraulic connections for cylinders 9 Cylinders with immersion heaters 11 Cylin...

Page 4: ...ater 35 kg 45 kg 55 kg 70 kg CONNECTIONS Cold Water Inlet Domestic Hot Water Flow Hot Water Secondary Returns Primary Flow from Boiler Primary Return to Boiler 2 MAINTENANCE WARNING BEFORE COMMENCING...

Page 5: ...it should be carried into position within its packaging and on its pallet Once in position the pallet should be removed The cylinder should be installed on a floor designed to take the weight of the c...

Page 6: ...s both hot and cold water and any other water discharge points showers etc Check operation of expansion relief valve on Cold Water Supply Kit by lifting manual release lever and discharging water Chec...

Page 7: ...See Table 2 below for sizing details of safety discharge pipe from our tundish Table 2 Sizing of copper discharge pipe D2 for common temperature relief valve outlet sizes Valve Outlet Size Minimum Si...

Page 8: ...t on the cold water supply The Unvented kit contains pressure reducing valve non return valve pressure relief valve and optional use balanced cold water connector It is good practice to fit the unvent...

Page 9: ...right to modify the characteristics of the equipment supplied without notice or as part of the continued development of our products 8 Fig 3 1 Unvented kit for EBS cylinders Fig 4 1 Unvented kit for...

Page 10: ...without notice or as part of the continued development of our products 10 11 Whilst in heating cycle using the immersion heater the Green selector switch LED will illuminate and extinguish once desir...

Page 11: ...low CPC 7 The desired temperature setting should now be set using the controls on the top of the cylinder or should be left on maximum if the hot water is controlled via our boiler controls Technical...

Page 12: ...We reserve the right to modify the characteristics of the equipment supplied without notice or as part of the continued development of our products 13 PRESSURE TEMPERATURE RELIEF VALVE...

Page 13: ...tics of the equipment supplied without notice as part of our continued development of products IMPORTANT This drawing to be read in conjunction with the full installation manuals supplied SECONDARY RE...

Page 14: ...We reserve the right to modify the characteristics of the equipment supplied without notice or as part of the continued development of our products 15...

Page 15: ...We reserve the right to modify the characteristics of the equipment supplied without notice or as part of the continued development of our products 16...

Page 16: ...ND BUILDING CONTROL INSPECTOR PRIOR TO INSTALLATION 300 mm minimum from Tundish to Bend Building Regulations requirements 200 mm minimum height above HepvO Valve 300 mm between pipe clips PIPE CLIP TO...

Reviews: