Intelligent Document Reader AT10Ki User Guide
Reader components
Page 16 of 41
The Gemalto AT10Ki can compensate for ambient light in most bright office environments and will work
without the hood attached.
Note that the hood can be fixed by using the glass mounting holes contact Gemalto support for more
information.
Status Indicator LEDs
The status LEDs are designed to make the reading process more intuitive both for untrained or infrequent
users and regular users. The LEDs
indicate the reader’s status and the progress of the read until the
point when the document can be removed from the reader. These LED sequences have been designed
to help users place documents correctly. During a read the following states can be seen:
LED Colour
Status
Description
Yellow
– landing
lights
Ready
Reader is ready to scan a document.
Yellow
–
progress bar
Busy
Reader is scanning a document and processing the data.
Green tick
Successful read
A known document type was presented and processing was
successful.
Red cross
Some data failed
to read
Document is of an unknown type or did not process properly.
The LEDs are also used to indicate self-test states during power up as follows:
LED Colour
Description
All LEDs off
Hardware failure, return to service centre if fault persists.
Red cross flashing
Self-test failure, error can be determined from flash sequence, return to service centre if
fault persists.
Red cross on
Self-test failure, return to service centre if fault persists.
2 Yellow LEDs
blinking
Device preparing for operation.