Rev. 00 03/19
OptiFlex Pro B
Fault clearance
49
Code
Description
Criteria
Remedy
H61
Supplementary air
reference position not
found
Throttle motor or needle
jammed, limit switch defective,
error in motor throttle
Contact a Gema service
center
H62
Electrode rinsing air
reference position not
found
Throttle motor or needle
jammed, limit switch defective,
error in motor throttle
Contact a Gema service
center
H63
Fluidizing air reference
position not found
Throttle motor or needle
jammed, limit switch defective,
error in motor throttle
Contact a Gema service
center
H64
Conveying air throttle
does not move
Short circuit in limit switch, motor
throttle defective
Contact a Gema service
center
H65
Supplementary air throttle
does not move
Short circuit in limit switch, motor
throttle defective
Contact a Gema service
center
H66
Electrode rinsing air
throttle does not move
Short circuit in limit switch, motor
throttle defective
Contact a Gema service
center
H67
Fluidizing air throttle does
not move
Short circuit in limit switch, motor
throttle defective
Contact a Gema service
center
H68
Conveying air position
lost
Lost steps, limit switch defective,
throttle motor defective
Contact a Gema service
center
H69
Supplementary air
position lost
Lost steps, limit switch defective,
throttle motor defective
Contact a Gema service
center
H70
Electrode rinsing air
position lost
Lost steps, limit switch defective,
throttle motor defective
Contact a Gema service
center
H71
Fluidizing air position lost
Lost steps, limit switch defective,
throttle motor defective
Contact a Gema service
center
Communication mainboard-gun:
H91
Communication error
mainboard-gun
Gun not connected
Gun, gun cable or Mainboard
defective
connect
Replace or contact Gema
Service
Help codes list
The last appeared four errors are stored in a list by the software. If an
error appears, which is already in the list, he will not be listed again.
Appearance of errors
It is possible that an error is only displayed for a short time, but after the
acknowledgement it will disappear. In this case, it's recommended to
switch off the control unit and switch it on again (reset by restarting).
Summary of Contents for OptiFlex Pro B
Page 12: ...Rev 00 03 19 12 Safety OptiFlex Pro B ...
Page 34: ...Rev 00 03 19 34 Operation OptiFlex Pro B ...
Page 36: ...Rev 00 03 19 36 Decommissioning Storage OptiFlex Pro B ...
Page 50: ...Rev 00 03 19 50 Fault clearance OptiFlex Pro B ...
Page 54: ...Rev 00 03 19 54 OptiSelect Pro GM04 OptiFlex Pro B ...
Page 62: ...Rev 00 03 19 62 Maintenance Repairs OptiFlex Pro B ...
Page 64: ...Rev 00 03 19 64 Fault clearance OptiFlex Pro B ...
Page 67: ...Rev 00 03 19 OptiFlex Pro B Spare parts list 67 OptiFlex Pro B Spare parts fig 17 ...
Page 75: ...Rev 00 03 19 OptiFlex Pro B Spare parts list 75 Inside back plate fig 23 OptiStar CG21 ...
Page 77: ...Rev 00 03 19 OptiFlex Pro B Spare parts list 77 Connecting material fig 24 ...
Page 88: ...Rev 00 03 19 88 Spare parts list OptiFlex Pro B OptiFlow IG07 spare parts fig 28 ...
Page 90: ...Rev 00 ...