Cleaning and maintenance
OptiFlex 2 V
Cleaning
WARNING:
If no dust mask or one of an insufficient filter class is worn when
cleaning the product, then the dust that is stirred up from the coat-
ing powder can cause respiratory problems.
- The ventilation system must be turned on for all cleaning work.
- A dust mask corresponding to filter class FFP2 or N95 at minimum
must be worn during any cleaning work.
Cleaning the fluidizing/suction unit
1. Remove the injector
2. Remove the fluidizing/suction unit
3. Clean the fluidizing/suction unit with compressed air. Also blow
off the suction tube with compressed air
4. Clean the injector (see therefore the injector user manual)
5. Reassemble the individual parts