V
03/13
OptiFlex 2 B
Initial start-up
•
25
Note:
To achieve maximum efficiency, we recommend avoided an overly
high powder volume where possible! The standard setting of 50%
and a total air volume of 4 Nm³/h is recommended at the start. The
total air volume is thereby kept constant automatically by the
control unit.
If values are entered that the equipment cannot implement, then the
operator is informed of this by a blinking in the relevant display and
a temporary error message!
10. Setting the electrode rinsing air
a) Press the key
The second display level will be shown
b)
too much electrode rinsing air
11. Setting the fluidization
a) Press the key
The second display level will be shown
b)
c) Check the powder fluidization in the powder container
The powder fluidization in the powder containers depends on
the powder characteristics, the humidity and the ambient air
temperature. Fluidizing and vibration start by switching on
the control unit.
WARNING:
If the fluidization has been incorrectly adjusted, then the coating
powder can create a dust cloud capable of causing respiratory
problems.
- Ensure proper setting of fluidization
12. Point the gun into the booth (not at the object to be coated),
press the gun trigger and visually check the powder output
13. Check whether everything is functioning correctly
approx.
0.1 Nm³/h
approx.
0.5 Nm³/h