Rev. 00 02/21
OptiCenter OC09
Start-up
57
No.
Parameters
Description
Value
3400
OptiCenter type
Selection of OptiCenter type
OC06
OC07
OC08
OC09
3401
US-Mesh: 140 µm
Selection of ultrasonic sieve with mesh size
140 µm
0 / 1
3402
US-Mesh: 200 µm
Selection of ultrasonic sieve with mesh size
200 µm
0 / 1
3403
US-Mesh: 250-300 µm
Selection of ultrasonic sieve with mesh size
250 µm or 300 µm.
0 / 1
3404
US-Mesh: > 500 µm
Selection of ultrasonic sieve with mesh size
500 µm or larger (XXX-1180 µm)
0 / 1
3405
Recovery- Freshpowder
sieving
The recovery powder is sieved by default.
0 = sieving inactive
1 = sieving recovery powder
2 = sieving recovery and fresh powder
3 = sieving fresh powder
0 / 1 / 2 / 3
3406
Additional powder hopper
Fresh powder hopper with level sensor
0 / 1
3407
Fresh powder system intern
Activates typical limits and default settings
for an internal fresh powder system.
0 / 1
3408
Fresh powder system extern
Activates typical limits and default settings
for an external fresh powder system.
0 / 1
3409
Vacuum cleaner
0 / 1
3410
Second OptiCenter
OptiCenter is configured as the second
OptiCenter in a MultiColor MCS01 system.
0 / 1
3412
Operating mode spray
manual
0 / 1
3414
level sensor
0 / 1
3417
Sieve PSxx
Activates typical limits and default settings
for an internal vibrating sieve.
0 / 1
3421
US-Mesh: Cannot be
deselected
xxx
0 / 1
3439
Number of injectors 1-12
Selection Number of injectors
1-12
1-24
3460
Delay Fresh powder demand
In coating mode with powder recovery
(spray), fresh powder is also fed into the
OptiHopper after the set time has elapsed
in addition to the recovery powder until the
powder level set at parameter 3440 is
reached again.
0-180 s
3461
Supervision Fresh powder
demand
If in automatic mode the powder level set in
parameter 3440 is not reached after the set
time has elapsed, an error message is
triggered.
0.3-5.0 min
Summary of Contents for OptiCenter OC09
Page 10: ...Rev 00 02 21 10 About these instructions OptiCenter OC09 ...
Page 52: ...Rev 00 02 21 52 Touch panel operating panel OptiCenter OC09 ...
Page 80: ...Rev 00 02 21 80 Maintenance Repairs OptiCenter OC09 ...
Page 84: ...Rev 00 02 21 84 Fault clearance OptiCenter OC09 ...
Page 88: ...Rev 00 02 21 88 Decommissioning Storage OptiCenter OC09 ...
Page 112: ...Rev 00 ...