Commissioning
OptiFlex A1 (AS07)
OptiFlex A1 Control cabinet
Combination examples:
-
1 OptiAir with max. 15 OptiStar control units
-
1 OptiAir with 2 OptiMove and 13 OptiStar control units
Start-up
General information
These general information serves to obtain an overview of the possible
OptiFlex A1 system combinations.
Detailed information will be found in the corresponding operating
manuals!
Power supply
-
As mains supply, a single phase alternating current is
required
-
If the OptiStar CG08 gun control unit is used, it can be
connected to tensions of 100-240 VAC
-
If the OptiMove reciprocator control unit is used, a mains
voltage of 230 VAC must be available
-
Frequencies of 50 or 60 Hz can be used
-
The input power value is evident in the technical data
section
-
All electrical components are implemented in accordance
to IP54 protection type regulations