![GEM R690 Assembly Instructions Manual Download Page 9](http://html1.mh-extra.com/html/gem/r690/r690_assembly-instructions-manual_2206356009.webp)
9 / 12
R690
5.1 Disassembling the actuator
WARNING
Actuator under spring
pressure!
³
Risk of severe injury or
death!
O
Only open the actuator
under a press.
1. Separate actuator from control medium.
2. Remove loose compressor
3
and
washer
47
.
3. Remove protective cap
SA2
.
4. Remove optical position indicator
SA1
.
5. Remove protective caps
29
.
6. Clamp actuator in a press.
CAUTION
Applied pressure too high!
³
Risk of breakage of actuator
top
10
!
O
Only use minimum required
pressure.
7. Undo and remove bolts
12
with
washers
13
between actuator top 10
and actuator base
16.
8. Slowly release the press.
9. Remove actuator top
10
.
10. Remove spring set
FP
from actuator
base
16
.
Important:
After disassembly, clean all parts
of contamination (do not damage
parts). Check parts for potential
damage, replace if necessary (only
use genuine parts from GEMÜ).
5.2 Replacement of spare parts
1. Disassemble actuator as described in
chapter 5.1, points 1-10.
2. Pull out actuator membrane assembly
manually upwards from actuator base
16
. The actuator membrane assembly
comprises actuator spindle
15
including
dowel pin
30
and adapter
31
, hexagon
nut
21
, washer
9
, upper and lower
membrane plate
6
, actuator membrane
5 Replacement of spare parts
Components highlighted in grey
are spare parts kit components.
28
5
10
6
14
15
4
12
47
30
31
21
27
17
16
22
SA2
SA1
13
29
3
22
9
FP
6
Summary of Contents for R690