C67
Information on the use of the diagram
The temperature / pressure diagram is only an orientation aid. The data refer to water as a working medium.
A change of operating conditions or other media may result in deviations. In case of doubt it is advisable to test the behavior of
the material under the definitive operating conditions by means of a test installation.
Temperatures under 0 °C can affect the operating speed negatively.
Temperature / pressure diagram - Valve body material PFA
(
HPW version
)
-4
14 32 50 68 86 104 122 140 158 176 194 212 230 248 266 284 302
-20
-10
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
1
2
3
4
5
6
7
15
30
45
60
75
90
105
Temperature [°C]
Temperature [°F]
Pr
essur
e
[P
SI]
Pr
essur
e
[bar]
ENGINEERED
WORKING RANGE
Temperature / pressure diagram - Valve body material PP
(
HPS version
)
-4 14 32 50 68 86 104 122 140 158 176
-20 -10 0 10 20 30 40 50 60 70 80
7
6
5
4
3
2
1
105
90
75
60
45
30
15
Temperature [°C]
Temperature [°F]
ENGINEERED
WORKING RANGE
Pr
essur
e
[bar]
Pr
essur
e
[P
SI]
-40
-20
0
20
40
60
80
100 120
8
6
4
2
0
120
90
60
30
0
-40
-4
32
68
104 140 176 212 248
Temperature [°C]
Pr
essur
e
[bar]
Temperature / pressure diagram - Valve body material PVDF
(
HPW version
)
Temperature [°F]
Pr
essur
e
[P
SI]
ENGINEERED
WORKING RANGE
25 / 40
Summary of Contents for C67 CleanStar
Page 38: ...C67 38 40 ...
Page 39: ...C67 39 40 ...