Gekasmetal AMANDA User Manual Download Page 5

                                                                                                                                          

                                                                                                                       

 

AIR HEATER PELLET STOVE BY GEKASMETAL 

                                                                                  

 

Page 5

 

 

• 

Keep this manual in a safe place, since it is an integral part of the product. If the product is sold or transferred to another user make sure that the manual will accompany 

the product.  

 

 

 

REGULAR USE 

The appliance functions only with wood pellets 6mm and it should be installed in internal areas. 

 

REFERENCE STANDARDS 

The installation should comply with: 

 

EN 14785 (2006) heat generators fueled with wood or other solid fuels  

This European Standard determines the requirements related to the design, construction, safety and efficiency, instructions and signalization, as well as   the related testing 
methods and the fuels, for the testing of residential heaters that function with aggregations of wood, with thermal power up to  50 kW . 
 
These appliances may be independent or nested for the inflow of heating into the area in which they are installed and they can function either with natural release or with 
the support of combustion air fan. Furthermore, if they are equipped with a boiler, they can provide hot water or/and central heating. These appliances burn wood pellets 
only, according to the instructions of the constructor. They function with closed refractory doors.  
 Appliances that are not mechanically powered and burn fossil fuels, peat briquettes and natural or altered tree trunks are not included in this European, but they are covered 
by EN 13229 and EN 13240. 
 

NOTE 

These appliances may include irremovable fuel funnel or be combined with an external fuel funnel.   

 

GUARANTEE TERMS  

The company provides a guarantee of the appliance, with the exception of the parts that are subjected to natural wear as it is determined below, for a period of time of two 
years from the moment of purchase, which is confirmed with the presence of a side document that includes the name of the seller and the date of the purchase. Guarantee 
cover is valid if the product has been installed and checked by professional personnel, according to the detailed instructions which are provided in this manual that comes 
along with the appliance. The term «guarantee» refers to the (free of charge) replacement or repair of the parts of the appliance which are admitted as defective by 
construction. 

RESTRICTIONS  

The above-mentioned guarantee does not cover parts of the electric and electronic components and ventilators which are covered for 1 year from the moment of purchase 
the receipt of which is provided, as it is determined above.  The guarantee does not cover the components of the appliance that are subjected to natural wear, including: 
gaskets, glass and all the parts that can be removed from the stove.  

The replacements can be covered by the guarantee for the time determined from the moment of purchase.   

EXCEPTIONS 

The guarantee does not cover any part of the appliance that can be damaged or destroyed, due to negligent use or incorrect maintenance or installation that does not comply 
with the instructions provided by the company. The company does not bear responsibility for any damaged may caused, directly or indirectly, on persons, animals or objects, 
as a result of non compliance with all the specifications determined in this manual, especially concerning the warnings related to installation, use and maintenance of the 
appliance. If the appliance does not function properly contact the local supplier and/or importer. Damages caused during the transfer or /and operation are excluded from 
the guarantee. The provided manual is the only reference for the use and installation of the appliance.  The guarantee is not valid in case of damage caused by violation of the 
instructions, atmospheric factors, natural disasters, electric discharge, fire, abnormalities of the electric system and non anticipated maintenance as it is indicated by the 
constructor. 

The company does not bear any responsibility if the product and any of its parts is used incorrectly or have been modified without license.  All the parts must be replaced with 
genuine replacements.  The request should be sent to the seller, who will convey it to the Technical Support Department.   

Only genuine replacements should be used.  

Regular maintenance is important.  

Warnings concerning the proper distribution of the product according to the European instruction 2002/96/

ΕΚ

 and its  posterior modification 2003/108 

ΕΚ

Summary of Contents for AMANDA

Page 1: ...AIR HEATER PELLET STOVE BY GEKASMETAL Page 1 AMANDA 9KW Manual...

Page 2: ...METAL The pellet stove is an ideal heating solution It uses advanced technology and it has been constructed according the highest standards with modern design that allows you to enjoy your heat with...

Page 3: ...r operator of the appliance should read and fully comprehend the content of this manual before attempting any use of it Mistakes or incorrect adjustments may cause dangerous conditions or and poor fun...

Page 4: ...ext ignition Do not clean the product with water Water could leak into the appliance and destroy the electric insulation causing electrocution Do not stand in front of the appliance for a long time Av...

Page 5: ...th the appliance The term guarantee refers to the free of charge replacement or repair of the parts of the appliance which are admitted as defective by construction RESTRICTIONS The above mentioned gu...

Page 6: ...the European market and guarantee that the following characteristics are being retained Thermal value 4 9 kWh kg Humidity max 10 of its weight Ash percentage max 0 5 of its weight Diameter 5 6 mm Len...

Page 7: ...here should be an ventilation opening The air pipes should comply with following requirements Be protected with racks metal nets etc without reducing however the useful part Be constructed in such way...

Page 8: ...ggested CONNECTION TO ELECTRIC NETWORK Before the connection of the appliance to electric network check if the electrical installation is equipped with ground and differential switch according to regu...

Page 9: ...cross flammable materials the above instructions should be followed SYMBOL DESCRIPTION HEIGHT mm b Minimum distance from combustible materials from the inside of the ceiling floor wall 500 B Minimum d...

Page 10: ...pe should allow the retrieval of soot it should be cleaned and be inspected after being dismantled or through the inspection openings if it is not accessible from the inside of the appliance ADDITIONA...

Page 11: ...ns only with negative pressure in relation to the environment and should be according to EN 14785 2006 Flue terminals The flue terminals should comply with the following requirements They should be se...

Page 12: ...N 14785 2006 In case of pellet appliances the fume extraction systems should have leak tightness if they use elements of double definition G and O with or without elastomeric sealing For the connectio...

Page 13: ...to remove it The glass should be cleaned using a dry cloth If needed you can use water and a soft detergent only if the glass is cold Once in a month clean the area behind the ash tank by removing th...

Page 14: ...that performed the actions of inspection or and maintenance along with contact information date and signature of the technician 5 TECHNICAL CHARACTERISTICS MODEL WOOD PELLET STOVE AMANDA DIMENSIONS Hx...

Page 15: ...causes exit without recording the value During the processing of text it causes exit without recording the text Prolonged press Switches off the boiler performing all necessary actions ignition combu...

Page 16: ...th Minus button it changes the current indications screen Main Screen Entries Screen Exits Screen 4 Minus Button Decrease and navigation button Single press Enables the screen for room temperature set...

Page 17: ...it should firstly be activated The control system is considered activated when it is at any phase except for the phase SHUTDOWN If it is deactivated the indication on the screen is SHUTDOWN If it is a...

Page 18: ...re then the controller moves to the INERTIA phase or the SHUTDOWN phase depending on whether it was enabled or disabled before the interruption of electrical supply voltage During the first ignition i...

Page 19: ...nd the combustion fans are adjusted automatically in order to achieve the desirable operation temperature Manually When a manual program has been selected then the control system is not enabled On the...

Page 20: ...he control system in this phase and for a small period of time preserve their former speed After this period of time and for the rest of the phase the combustion fan functions with maximum speed The s...

Page 21: ...The entry signals remain activated The system does not return in function if the error has not been removed by the user 22 Low Fumes Fume temperature below the limit for a specific period of time The...

Reviews: