MU-A-RectiRail DL2-rev01a-Gb
32
/ 44
x1, x5, x10 zoom
The curves displayed with these zoom factors are rectified.
Rectification allows measurements to be presented in the form of their difference
with the reference line based on the rail points measured under the 3rd and 98th
sensors, or the 1st and 100th sensors, according to the chosen parameter setting
in the Options (protected) menu.
In the first case, the 3rd and 98th values will thus always be at 0, else the 1st and
100th
values will be at 0.
On the curves presented above, the 3rd and 98th sensors are at 0.
XX zoom
This mode presents non-rectified values, unlike the other zoom factors.
The curve thus presents an “image of the differences” between the rule sensor
plane and the measured rail.
Schematically, the XX zoom presents a measurement corresponding to:
This mode can be used in the event of measurement problems (for example
display problems), as it can help identify the problematic measurement area.
Display area in XX zoom
100th sensor
1st sensor
Profile