6. Setting of the end stops

6.1. Install drive as described.
6.2. Connection of the setting cable

Connect adjusting cable to the connecting leader of the 

MODULARline Easy

always connect cores of identical colour here. The assignment of the direction 
keys 1 and 2 to the direction of rotation is dependent on the installation situa-
tion of the drive. Then connect the adjusting cable to the 230V mains.

6.3. Adjustment of the upper end position:

Press programming key until the LED blinks, (1 x blink, pause, 1 x blink, 
pause,...), then release the programming key. Run 

MODULARline Easy with 

the direction keys to the desired upper end position. Press programming key 
until the LED blinks, (2 x blinks, pause, 2 x blinks, pause,...), then release the 
programming key.
The upper end position is now adjusted and the programming mode for the 
lower end position is active.

6.4. Adjustment of the lower end position:

Run 

MODULARline Easy with the direction keys to the desired lower end 

position. Then press the programming key until the LED lights permanently, 
then release the programming key.
The lower end position is adjusted here und the adjustment process is finished.

6.5. The drive can now be connected to the 230V mains.

 

I

There is no need to first delete the end stops (memorised) if you wish to 

modify them.

Mains:
230 V

Setting cable
M56....

Service
terminals

Connecting cable
to limit stop

1

2

Programming
key

LED

Hirschmann coupling

Adaption cable
M56B265

Summary of Contents for GEIGER-Easy

Page 1: ...E Bedienungsanleitung Operating Instructions Manuel d utilisation Manual de instrucciones Istruzioni per l uso EN FR ES IT Tubular motor GEIGER MODULARline Motor control GEIGER Easy GR45 E01 for rolli...

Page 2: ...3 2 Guarantee 3 3 Safety information 3 4 Intended use 4 5 Installation instructions 5 6 Setting of the end stops 6 7 Obstacle detection 7 8 Technical data 8 9 Declaration of conformity 8 10 Informatio...

Page 3: ...w these instructions The instructions should be kept f f This appliance is not to be used by persons including children whose physical sensorial or mental capacities are impaired or who have no expe r...

Page 4: ...put out of operation f f If the tubular motor is controlled by a switch or pushbutton the switch or pushbutton must be mounted within eyeshot of the tubular motor The switch or pushbutton must not be...

Page 5: ...n of limit stop and short motor 1 The drive must first be disconnected from the mains 2 Twist the unlocking lever with a 5 mm hexagon socket key 3 The short motor can then be removed simply from the l...

Page 6: ...ion keys to the desired upper end position Press programming key until the LED blinks 2 x blinks pause 2 x blinks pause then release the programming key The upper end position is now adjusted and the...

Page 7: ...he installation due to ageing soiling cold or heat are thus automatically taken into consideration This process takes place for both running directions independently of one another If a travel movemen...

Page 8: ...tal length 515 5 mm 545 5 mm Operating type S2 4 min S2 5 min Diameter 45 mm 45 mm Weight approx 1 520 kg approx 1 670 kg Subject to technical modifications D E V gepr fte Sicherheit 9 Declaration of...

Page 9: ...n These cables should not be used if they are likely to touch metal parts that can heat up to tempera tures exceeding 100 C Connecting cables with plug connectors of the Hirschmann Company type STAS 3...

Page 10: ...down to be tested by a specialist electrician Instead of in the upwards direction motor runs downwards The control leads are interchanged Exchange black brown control leads Motor only runs in one dir...