6. Setting of the end stops
6.1. Install drive as described.
6.2. Connection of the setting cable
Connect adjusting cable to the connecting leader of the
MODULARline Easy;
always connect cores of identical colour here. The assignment of the direction
keys 1 and 2 to the direction of rotation is dependent on the installation situa-
tion of the drive. Then connect the adjusting cable to the 230V mains.
6.3. Adjustment of the upper end position:
Press programming key until the LED blinks, (1 x blink, pause, 1 x blink,
pause,...), then release the programming key. Run
MODULARline Easy with
the direction keys to the desired upper end position. Press programming key
until the LED blinks, (2 x blinks, pause, 2 x blinks, pause,...), then release the
programming key.
The upper end position is now adjusted and the programming mode for the
lower end position is active.
6.4. Adjustment of the lower end position:
Run
MODULARline Easy with the direction keys to the desired lower end
position. Then press the programming key until the LED lights permanently,
then release the programming key.
The lower end position is adjusted here und the adjustment process is finished.
6.5. The drive can now be connected to the 230V mains.