12. What to do if…
Problem
Solution
Motor does not run.
• Motor not plugged in.
Please check the plug connection.
• Check connecting cable for possible
damage.
• Check the mains voltage and allow
the cause of the voltage break down
to be tested by a specialist
electrician.
Instead of in the upwards direction,
motor runs downwards.
• The control leads are interchanged.
Exchange black/brown control leads.
Motor only runs in one
direction.
• Motor in the end position.
Run motor in the opposite direction.
After running several times,
the motor breaks down and
no longer responds.
• The motor became too hot and has
switched off.
Try it again after a cooling time of
about 15 min.
The motor only makes 1/2
a rotation.
• Magnetic shaft not installed.
Withdraw switch, insert magnetic
shaft into motor
Adjustment does not work.
• Magnetic shaft not installed.
Withdraw switch, insert magnetic
shaft into motor.
• No adjusting cable.
For adjusting the MODULARline
Easy you need the adjusting cable
M56K144.