GEIGER GEIGER-Easy Operating Instructions Manual Download Page 1

1

www.geiger.de

EN

EN

DE

Bedienungsanleitung

Operating Instructions

Manuel d’utilisation

Manual de instrucciones

Istruzioni per l’uso

EN

FR

ES

IT

Tubular motor: 

GEIGER-MODULARline

Motor control: 

GEIGER-Easy (GR45..E01)

for rolling shutters and screens

Summary of Contents for GEIGER-Easy

Page 1: ...E Bedienungsanleitung Operating Instructions Manuel d utilisation Manual de instrucciones Istruzioni per l uso EN FR ES IT Tubular motor GEIGER MODULARline Motor control GEIGER Easy GR45 E01 for rolli...

Page 2: ...3 2 Guarantee 3 3 Safety information 3 4 Intended use 4 5 Installation instructions 5 6 Setting of the end stops 6 7 Obstacle detection 7 8 Technical data 8 9 Declaration of conformity 8 10 Informatio...

Page 3: ...w these instructions The instructions should be kept f f This appliance is not to be used by persons including children whose physical sensorial or mental capacities are impaired or who have no expe r...

Page 4: ...put out of operation f f If the tubular motor is controlled by a switch or pushbutton the switch or pushbutton must be mounted within eyeshot of the tubular motor The switch or pushbutton must not be...

Page 5: ...n of limit stop and short motor 1 The drive must first be disconnected from the mains 2 Twist the unlocking lever with a 5 mm hexagon socket key 3 The short motor can then be removed simply from the l...

Page 6: ...ion keys to the desired upper end position Press programming key until the LED blinks 2 x blinks pause 2 x blinks pause then release the programming key The upper end position is now adjusted and the...

Page 7: ...he installation due to ageing soiling cold or heat are thus automatically taken into consideration This process takes place for both running directions independently of one another If a travel movemen...

Page 8: ...tal length 515 5 mm 545 5 mm Operating type S2 4 min S2 5 min Diameter 45 mm 45 mm Weight approx 1 520 kg approx 1 670 kg Subject to technical modifications D E V gepr fte Sicherheit 9 Declaration of...

Page 9: ...n These cables should not be used if they are likely to touch metal parts that can heat up to tempera tures exceeding 100 C Connecting cables with plug connectors of the Hirschmann Company type STAS 3...

Page 10: ...down to be tested by a specialist electrician Instead of in the upwards direction motor runs downwards The control leads are interchanged Exchange black brown control leads Motor only runs in one dir...