81901 “MSW_GPC-40/600A”_03-2021_ENG_page 48
3.13.4.
Alarm hysteresis
Address
Format
GPC-OP
menu
Acronym
Global /
M/E1/E2
GF_eXpress menu
Attribute
Retentive
Type
Unit of mea
-
surement
Default
Single-
node
Multi-
node
Description
1211
187
16 bit
05.01.26
Hy.1
M
MainMenu
→
M
→
Alarms
→
AL1...AL8 alarms
→
AL1
→
Hy.1_1
R/W
■
Float *
s.p. *
sec.
min.
1
2235
05.02.26
E1
MainMenu
→
E1
→
Alarms
→
AL1...AL8 alarms
→
AL1
→
Hy.1_2
4283
05.03.26
E2
MainMenu
→
E2
→
Alarms
→
AL1...AL8 alarms
→
AL1
→
Hy.1_3
1212
188
16 bit
05.01.27
Hy.2
M
MainMenu
→
M
→
Alarms
→
AL1...AL8 alarms
→
AL2
→
Hy.2_1
R/W
■
Float *
s.p. *
sec.
min.
1
2236
05.02.27
E1
MainMenu
→
E1
→
Alarms
→
AL1...AL8 alarms
→
AL2
→
Hy.2_2
4284
05.03.27
E2
MainMenu
→
E2
→
Alarms
→
AL1...AL8 alarms
→
AL2
→
Hy.2_3
1213
189
16 bit
05.01.28
Hy.3
M
MainMenu
→
M
→
Alarms
→
AL1...AL8 alarms
→
AL3
→
Hy.3_1
R/W
■
Float *
s.p. *
sec.
min.
2
2237
05.02.28
E1
MainMenu
→
E1
→
Alarms
→
AL1...AL8 alarms
→
AL3
→
Hy.3_2
4285
05.03.28
E2
MainMenu
→
E2
→
Alarms
→
AL1...AL8 alarms
→
AL3
→
Hy.3_3
1083
59
16 bit
05.01.29
Hy.4
M
MainMenu
→
M
→
Alarms
→
AL1...AL8 alarms
→
AL4
→
Hy.4_1
R/W
■
Float *
s.p. *
sec.
min.
1
2107
05.02.29
E1
MainMenu
→
E1
→
Alarms
→
AL1...AL8 alarms
→
AL4
→
Hy.4_2
4155
05.03.29
E2
MainMenu
→
E2
→
Alarms
→
AL1...AL8 alarms
→
AL4
→
Hy.4_3
1234
210
16 bit
05.01.30
Hy.5
M
MainMenu
→
M
→
Alarms
→
AL1...AL8 alarms
→
AL5
→
Hy.5_1
R/W
■
Float *
s.p. *
sec.
min.
1
2258
05.02.30
E1
MainMenu
→
E1
→
Alarms
→
AL1...AL8 alarms
→
AL5
→
Hy.1_2
4306
05.03.30
E2
MainMenu
→
E2
→
Alarms
→
AL1...AL8 alarms
→
AL5
→
Hy.5_3
1235
211
16 bit
05.01.31
Hy.6
M
MainMenu
→
M
→
Alarms
→
AL1...AL8 alarms
→
AL6
→
Hy.6_1
R/W
■
Float *
s.p. *
sec.
min.
1
2259
05.02.31
E1
MainMenu
→
E1
→
Alarms
→
AL1...AL8 alarms
→
AL6
→
Hy.6_2
4307
05.03.31
E2
MainMenu
→
E2
→
Alarms
→
AL1...AL8 alarms
→
AL6
→
Hy.6_3
1236
212
16 bit
05.01.32
Hy.7
M
MainMenu
→
M
→
Alarms
→
AL1...AL8 alarms
→
AL7
→
Hy.7_1
R/W
■
Float *
s.p. *
sec.
min.
1
2260
05.02.32
E1
MainMenu
→
E1
→
Alarms
→
AL1...AL8 alarms
→
AL7
→
Hy.7_2
4308
05.03.32
E2
MainMenu
→
E2
→
Alarms
→
AL1...AL8 alarms
→
AL7
→
Hy.7_3
1237
213
16 bit
05.01.33
Hy.8
M
MainMenu
→
M
→
Alarms
→
AL1...AL8 alarms
→
AL8
→
Hy.8_1
R/W
■
Float *
s.p. *
sec.
min.
1
2261
05.02.33
E1
MainMenu
→
E1
→
Alarms
→
AL1...AL8 alarms
→
AL8
→
Hy.8_2
4309
05.03.33
E2
MainMenu
→
E2
→
Alarms
→
AL1...AL8 alarms
→
AL8
→
Hy.8_3
The parameter sets the hysteresis for generic alarms AL1...AL8 of modules GPC-M, GPC-E1 and GPC-E2. The alarm and module con-
cerned depend on the address used.
*) The range of valid values for the threshold and the position of the decimal point may vary according to the reference variable chosen for
the alarm
Ax.r
(with x = 1...8).
min...max
:
-
99.9
..
.
99.9
If symmetrical alarm
0
..
.
999
With
unit of measurement in seconds, if +32 in parameter
Ax.t
, with x = alarm number
0
..
.
999
With unit of measurement in minutes, if +64 in parameter
Ax.t
, with x = alarm number
For further information on symmetrical alarms, see paragraph “4.4.1. Generic alarms AL1...AL8”.