![gefran CAN-IO Installation And User Manual Download Page 32](http://html.mh-extra.com/html/gefran/can-io/can-io_installation-and-user-manual_2205693032.webp)
32
80990B_MHW_CAN-IO_12-2016_ENG
Create the codes to suit the device configuration required
CAN-IO
CAN-IO-D ## # ## ## # # A # # # # ## ## ## # # - # # #
Digital inputs (max 24)
+24 VDC
00 / 03 / 06 / 09 / 12 / 15 / 18 / 21 / 24
Fast counters (max 6)
Fast counter 50 kHz
0 / 3 / 6
PWM outputs (max 8)
24 VDC 1 A, xxxx kHz max
0 / 2 / 4 / 6 / 8
Digital outputs (max 16)
+24 VDC 0,5 A
00 / 02 / 04 / 06 / 08 / 10 / 12 / 14 / 16
+24 VDC 2 A
00 / 02 / 04 / 06 / 08 / 10 / 12 / 14 / 16
Relay, 250 VAC 5 A
0 / 2 / 4 / 6 / 8
Temperature inputs (max 10)
Thermocouples J, K, S, N, T, E, B, R
00 / 02 / 04 / 06 / 08 / 10
Pt100
00 / 02 / 04 / 06 / 08 / 10
Pt1000
00 / 02 / 04 / 06 / 08 / 10
Analogue outputs (max 8)
±10 V
0 / 2 / 4 / 6 / 8
0-20 mA
0 / 2 / 4 / 6 / 8
DIN runner
Absent
0
Present
1
IP protection rating
Absent
0
IP20
1
Connector
Screw terminals
1
Click, female, 12-pole
2
Comb
3
Analogue inputs (max 8)
±10 V
0 / 2 / 4 / 6 / 8
0-20 mA
0 / 2 / 4 / 6 / 8
Strain gauge 3,3 mV/V
0 / 2 / 4 / 6 / 8
Potentiometer
0 / 2 / 4 / 6 / 8
Code examples
CAN-IO-D 09 3 00 00 0 4 A 0 0 0 0 00 00 00 0 0 - 0 0 2
9 digital inputs, 3 fast counters, 4 PWM outputs; assembly
on plate; click connectors
CAN-IO-D 00 0 00 00 4 0 A 0 0 0 2 04 00 00 0 2 - 1 1 1
4 relay outputs, 2 potentiometer inputs, 4 thermocouple inputs,
2 current analogue outputs 0-20 mA; assembly on DIN runner;
IP20 protection rating; screw terminals
DIGITAL IO
ANALOGUE IO
PHYSICAL CHARACTERISTICS
ATTENTION!
The total number of inputs
and Outputs cannot be more than 40.