![gefran CAN-IO Installation And User Manual Download Page 10](http://html.mh-extra.com/html/gefran/can-io/can-io_installation-and-user-manual_2205693010.webp)
10
80990B_MHW_CAN-IO_12-2016_ENG
ANALOGUE INPUT
IN VOLTAGE ±10 V
Max number
8 (orderable in groups: 2, 4, 6, 8)
Type
Single-ended voltage ±10 V
Input filter
Low-pass, 3rd order
Cutting frequency: 20 Hz
Input impedance
> 1 MΩ
Sampling time
(for all channels)
5 ms
Output format
Type: INT
Resolution: 13 bit (-4096 … 4095)
LSB: 2,44 mV
Max error @ 25 °C
±0,5% scale bottom
Protections
Polarity inversion: yes
Overvoltage: max 1 kV per 1 ms
Electric insulation
Channel-channel: no
Channel-bus: 2 kV
ANALOGUE INPUT
IN CURRENT
0/4 … 20 mA
Max number
8 (orderable in groups: 2, 4, 6, 8)
Type
Current 0 ... 20 mA
Input filter
Low-pass, 3rd order
Cutting frequency: 20 Hz
Input impedance
100 Ω
Sampling time
(for all channels)
5 ms
Output format
Type: UINT
Resolution: 14 bit (0 … 20 mA: 0 … 16384
4 … 20 mA: 3277 … 16384)
LSB: 4,88 μA
Max error @ 25 °C
±0,5% fondo scala
Protections
Polarity inversion: yes
Overvoltage: max 1 kV per 1 ms
Electric insulation
Channel-channel: no
Channel-bus: 2 kV
POTENTIOMETER
ANALOGUE INPUT
Max number
8 (orderable in groups: 2, 4, 6, 8)
Type
Potentiometer 2 kΩ min.
Transducer power
5 V, 150 mA max
Input filter
Low-pass, 3rd order
Cutting frequency: 20 Hz
Input impedance
> 1 MΩ
Sampling time
(for all channels)
5 ms
Output format
Type: UINT
Resolution: 12 bit
LSB: 1,22 mV
Max error @ 25 °C
±0,5% scale bottom
Protections
Polarity inversion: yes
Overvoltage: max 1 kV per 1 ms
Electric insulation
Channel-channel: no
Channel-bus: 2 kV