GS120-MAN-14V05 (0307)
Copyright © 2014 Gedge Systems
21
3rd character from end / 2nd character from end / End of string character
Some output strings may have fi xed end characters, as opposed to fi xed start
characters. In this case, the 3rd to last, 2nd to last and/or end character may be
specifi ed. Any/all of these characters may be set to
Ignore
if they are not fi xed.
The GS120 will check that all three end characters match their values (if speci-
fi ed), before the string is accepted.
Count from end character back to start of weight string
This option is usually used in conjunction with the End of string, 2nd to last, or
3rd to last character options. Once the end of the string has been detected, you
may specify where the weight information is in the string by counting the num-
ber of characters back from the last character to the start of the weight string.
If this option is not applicable, select
Ignore
from the count options.
Last resort character & count options
Character
Ignore
01H 02H(STX) 03H(ETX) 04H 05H 06H 07H 08H 09H(TAB)
0AH(LF) 0BH 0CH 0DH(CR) 0EH 0FH 10H 11H 12H 13H 14H 15H
16H 17H 18H 19H 1AH 1BH(ESC) 1CH 1DH 1EH 1FH 20H(SPC)
! 22H # $ % & ' ( ) * + , - . /
0 1 2 3 4 5 6 7 8 9
: ; < = > ? @
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
[ 5CH ] ^ _ `
a b c d e f g h i j k l m n o p q r s t u v w x y z
{ | } 7EH 7FH
Count
Ignore
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40