Geco GH10TA User Manual Download Page 16

GH10TA USER MANUAL

 

PAGE  

16

 

Issue I 

 July 2017

 

The GH10TA Controller allows connection of an additional pump to control the Hot Utility Water (HUW) 

in the boiler. 

8.1.

 

Instalation and Connections 

To use the Hot Utility Water (HUW) heating option, perform the following actions: 

1.

 

connect the boiler according to the enclosed diagram (

 section 6.1.1 page 8). 

2.

 

install the HUW temperature sensor in the HUW storage 

 

We recommend mounting HUW temperature sensor in GECO 

measuring drain.   

You can not mounted temperature sensors in measuring drain with 

water or oil !!! 

 

3.

 

connect the HUW temperature sensor to the Controller at the appropriate 
terminals as shown in Fig. 2  

4.

 

configure the HUW pump for operation (

 section 8.2 page 15). 

 

8.2.

 

Configuration of Additional Pump 

This procedure allows you to connect an additional pump that can be used as a mixing pump or a Hot 

Utility Water (HUW) pump operating with or without higher priority. 

The HUW pump is started when the boiler outlet water temperature is higher than 40°C and higher 

than the water in the HUW boiler (to prevent cooling of the HUW boiler), and the HUW boiler temperature 

is lower than the temperature set in the 

U4

 setting (

 section 

7.5

 page 14). 

Pump operation is indicated by a dot on the display next to the fan symbol.  

If the boiler room is configured as shown in the diagram (

 section 6.1.1 page 8) then the boiler 

controller has no external alarm output, but allows to view the HUW boiler temperature   

by pressing 

 .  

 

 

Use the following procedure to program operation of an additional pump in the Controller: 

 

 

HUW temperature sensor is additional equipment and it’s not includes 

to the standard set controller GH10TA. 

Additional equipment can be delivery according with additional order. 

Summary of Contents for GH10TA

Page 1: ...licable Instructions before connecting and starting up any of our products Should any doubts arise please contact our Company between 8 a m and 4 p m Attention At the bottom of each page you will find...

Page 2: ...BOILER BURNOUT DETECTION 13 6 8 MAXIMUM FEEDER TEMPERATURE DETECTION 13 7 USER SETTINGS 14 7 1 BOILER TEMPERATURE SETTING U0 14 7 2 FEEDER STANDSTILL DURATION U1 14 7 3 MAINTAIN PERIOD U2 14 7 4 FAN S...

Page 3: ...ation have the following graphic forms Warning This symbol is used when it is necessary in described instructions to follow the sequence of carried out operations The unit may be damaged or destroyed...

Page 4: ...BY USING BUTTON ACTIVATE ALL BUTTON ON PANEL TOUCH KEYBORD TAKES PLACE AFTER TOUCH EACH OF THEM AND HOLD FOR MOMENTS ON OFF MANUAL CONTROL AUTO OPERATION INDICATOR MANUAL FAN AND CH PUMP ACTIVATION IN...

Page 5: ...s and other different disturbances The GH10TA Controller is fitted with inputs 1 boiler output water temperature measurement NTC sensor 2 fuel feeder temperature measurement NTC sensor 3 HUW boiler re...

Page 6: ...g varistor Omission of this security measure may result in malfunction or damage to the controller output 4 ELECTRICAL SYSTEM AND CONNECTION RULES 1 The boiler room should be equipped with a 230V 50Hz...

Page 7: ...d After calibration process the device performs a 3 second start sequence during which it displays various information including the firmware version When the start sequence is complete the controller...

Page 8: ...ory settings Table 1 Factory settings table Parametr Opis parametru Min Max Krok Nastawa fabryczna U00 Boiler temperature setting F03 F04 1 C 60 C U01 Feeder standstill duration 5 250 1s 30s U02 Maint...

Page 9: ...ral Heating cycle HUW cycle INPUTS OUTPUTS T1 Boiler temp P1 Fuel feeder T2 Feeder temp P2 Fan T3 HUW temp P3 HUW pump C1 Reed relay P4 CH pump 6 1 2 Central Heating cycle mixing pump INPUTS OUTPUTS T...

Page 10: ...40 C Turning the CH pump on and its operation is indicated by a vertical line at the left side of the Controller main display screen The Controller turns off the pump when the water temperature drops...

Page 11: ...pump is indicated by a horizontal line at the bottom of the Controller main display screen Pressing causes the Controller to switch from automatic to manual mode and immediately stops the fan the feed...

Page 12: ...HUW return temperature sensor failure AL9 No feeder rotation reed switch failure AL11 Maximum feeder temperature exceeded AL12 Boiler overheating AL13 Boiler burnout 6 6 Power Failure After a power fa...

Page 13: ...er enters the AL13 alarm condition 6 8 Maximum Feeder Temperature Detection The GH10TA Controller is equipped with an additional option of protecting from temperature rise in the fuel feeder above the...

Page 14: ...U2 setting 7 3 Maintain Period U2 This is the period of time after which the Controller activates the feeder and fan for the period set by the manufacturer for the MAINTAIN mode to prevent burning ou...

Page 15: ...th Legionella pneumophilia bacterium on HUW installation This function is available for users when value F00 service parameter was adjust on 02 03 or 04 The Legionella bacterium growth in water enviro...

Page 16: ...dure allows you to connect an additional pump that can be used as a mixing pump or a Hot Utility Water HUW pump operating with or without higher priority The HUW pump is started when the boiler outlet...

Page 17: ...room During blockade position C H pump stay off after 4 minutes for the moment when temperature in room is reached short circuit contact The boiler start working in maintain operation mode The contro...

Page 18: ...Controller to resume operation you have to after resetting the limiter press twice pressing for the first time cancels the alarm and disables the Controller pressing for the second time reactivates t...

Page 19: ...RICAL AND ELECTRONIC EQUIPMENT CAUTION This symbol placed on the product or its packaging indicates the need for selective collection of worn out electrical and electronic equipment It means that this...

Page 20: ...P P U H Geco Sp z o o Cholerzyn 376 32 060 Liszki Poland ph 012 636 98 11 636 12 90 fax 012 636 20 02 http www geco pl e mail geco geco pl...

Reviews: