16
Electrical wiring for North American models
Main electrical box
GFCI panel
Warning!
For units for use in other than single-family
dwellings, a clearly labeled emergency switch
shall be provided as part of the installation
The switch shall be readily accessible to the
occupants and shall be installed at least 5' (152 m)
away, adjacent to, and within sight of the unit
-----
This product must always be connected to a
circuit protected by a ground fault interrupter
Proper wiring of the electrical service box,
GFCI and Y Series terminal block is essential!
Check your electrical code for local regulations
Only copper wire should be used, never
aluminum
-----
Disposal of the product
The appliance (or the product) must be
disposed of separately in accordance with the
local waste disposal legislation in force
To install the wiring for the Y Series spa control, you'll
need a Phillips screwdriver and a flat screwdriver
Loosen the screws of the spa pack cover and remove it
Remove 5 1/2" (142 mm) of cable insulation Strip away
1" (25 mm) of each wire insulation Pull the cable through
the cutout of the box and secure it with a strain relief
(1" NPT strain relief; hole diameter: 1335" [339 mm])
(For CE use an IEC certified plastic bushing that will
maintain the IPX5 rating)
Make sure that only the uncut sheathing is clamped
at this opening Make sure that the terminal block case
clamps are lowered before inserting wires
Push the color-coded wires into the terminals
as indicated on the sticker and use the flat screwdriver
to tighten the screws on the terminals
After making sure wire connections are secure, push
them back into the box and replace the cover Tighten
the screws of the spa pack cover Do not over tighten
cover screws (torque to 8inlb max [09 Nm])
Connect the bonding conductor to the bonding lug
on the front of the Y Series spa pack (a grounded
electrode conductor shall be used to connect the
equipment grounding conductors)
bonding lug
Electrical wiring for all models
Y Series wiring