30
Gebwell GEMINI
11.4
User levels
The controller features specified user levels, which enables that
only corresponding user groups can change settings. The device
is mainly used on
End user
–level. The mechanic installing the
heat pump uses device on
Expert –
level. Different user levels
can be accessed from
Service/settings –menu.
11.5
Heating settings
The room temperature is dependent of several factors. During
warn seasons, the heat reflected from the sun, and heat given off
by people and various devices, often is enough to keep the room
temperature at a sufficient level. When the air cools down, a
heating system is needed. The colder it is outside, the warmer
the water is that circulates in the heating system. For the room
temperature to be at the right level, the basic settings must be
correct.
ADJUSTING WITH A HEATING CURVE
The starting point of the heating curve is the heat pump’s
damped outdoor temperature
(average temperature of 15h) and
the heating system’s measured output water temperature. The
slope of the automation’s curve can be seen at the intersection
point of the two values. This is separately set for each heating
area.
The settings are made in the Maintenance/settings menu
NOTE! The heating curve setting is based on a room tempera-
ture of 20°C. If the room temperature set point is changed, the
heating curve is changed automatically according to the new
value.
Example values for adjusting the slope of the heating curve:
Factory setting: 0,5
Floor heating: 0,3 – 0,5
Radiator heating: 0,5 – 1,0
Air heating: 0,5 – 1,0
Room temperature change
If you would like to decrease or increase the room temperature
either temporarily or permanently, do this by changing the
Com-
fort set point.
NOTE!
Floor heating or radiator heating thermostats may limit
the room temperature rise, so that they must also be adjusted
higher.
Readjusting the default settings
If the desired room temperature is not obtained, it is necessary to
re-adjust.
Cold weather:
- If the room temperature is too low, increase the
heating
curve slope
value.
Summary of Contents for GEMINI 40
Page 1: ...Installation Operation and Maintenance Manual GEMINI Heat Pump WWW GEBWELL FI...
Page 57: ...v1 6 29082018 57 20 ENERGY LABELS...
Page 58: ......
Page 59: ......
Page 60: ......
Page 61: ......
Page 62: ......
Page 63: ......
Page 64: ......
Page 65: ......
Page 66: ......
Page 67: ......
Page 68: ......
Page 69: ......
Page 70: ......
Page 71: ......
Page 72: ......