Replacing the spray nozzle and cleaning the opening of the spray arm
1 Lift up the WC seat and WC lid.
2 Press the <service> button on the remote control.
Result
The spray arm extends without spraying any water.
3 Hold the spray arm with one hand and carefully remove the spray nozzle with the
other.
4 Clean and de-scale the spray nozzle or replace it.
5 Press the <service> button.
Result
The spray arm returns to its starting position and the dryer arm extends without the
fan being activated.
6 Press the <service> button.
Result
The dryer arm returns to its starting position.
7 Clean the opening of the spray arm.
8 Press the <service> button.
Result
The spray arm extends without spraying any water.
9 Connect the spray nozzle to the spray arm.
10 Press the <service> button.
Result
The spray arm returns to its starting position and the dryer arm extends without the
fan being activated.
11 Press the <service> button.
Result
The dryer arm returns to its starting position.