background image

16

English

English

CONTROL

GENERATOR SWITCH

RECOIL STARTER

To start the engine, pull the starter grip lightly until 

resistance is felt, then pull briskly

NOTICE

Do not allow the starter grip to snap back against the 

engine. Return it gently to prevent damage to the 

starter.

FUEL VALVE

The fuel valve controls fuel flowing from the fuel tank 

to carburetor. Be sure to return the lever to “OFF” 

after stopping the engine.

CHOKE LEVER

The choke lever is used to provide an enriched fuel 

mixture when starting a cold engine. Slowly put the 

choke lever to “OPEN” position after the engine is 

started.

AC CIRCUIT BREAKER/OVERCURRENT 

PROTECTOR

The overload current will automatically switch off 

circuit breaker to avoid short circuiting of the load or 

overload. If the indicator of AC Overcurrent Protector 

is raised, the Overcurrent Protector is now in the 

“OFF” position. Press the button of AC Overcurrent 

Protector to the “ON” position again a few minute 

later.  If the circuit breaker is switched OFF 

automatically, switch the circuit breaker ON again.

GROUND TERMINAL

This ground terminal is dedicated to reliably 

grounding the whole generator.

OIL ALERT SYSTEM

The oil alert system is especially designed to 

prevent engine damage caused by an insufficient 

amount of oil in the crankcase. When the oil level 

in the crankcase fall down below the safe limit, the 

oil alert system will automatically shut down the 

engine(though the generator switch still remain 

in the ON position), so that the engine can’t be 

damaged due to the insufficient amount of oil.

GENERATOR OPERATION

Generator operation environment:

·  Temperature:-15°C - 40°C.

·  Humidity: below 95%.

·  Height above sea level: below 1,000m  

(If the area is over 1,000m high, the power should 

be lowered for operation).

 

CONNECTION TO THE HOUSEHOLD POWER 

SUPPLY

When connecting the generator to a household power 

supply, connection must be made by a qualified 

electrician. After connecting, carefully check electric 

connection for their safety and reliability, if not, 

damage to the generator,burning and firing may be 

caused.

Summary of Contents for 570752

Page 1: ...POWERMAN 8500 GR ES ART NR 570752 MANUAL...

Page 2: ...ndboken og varsel symboler p aggregatet ikke dekke alle farlige forhold Hvis vi ikke gir ekstra forsiktighetsregler for operasjonsprosedyrer metoder eller teknikker betjen generatoren p en slik m te a...

Page 3: ...rs klaring rundt aggregatet SIKKERHETSKRAV Forsikre deg om at elektrisk utstyr som ledninger og kontakter er i forskriftesmessig stand Sikringene p det elektriske utstyret som skal kobles p aggregatet...

Page 4: ...har stoppet aggregatet CHOKE Chockhendelen s rger for tilf re mere drivstoff ved oppstart av kald motor Skyv chockhendelen sakte tilbake til PEN posisjon etter at motoren har startet SIKRING OG OVERB...

Page 5: ...egatet b r ikke brukes p plasser som ligger h yere enn 1000 moh Ved bruk over 1000 moh vil aggregatets ytelse synke TILKOBLING TIL STR MNETT Hvis generatoren skal kobles til str mnettet hjemme som en...

Page 6: ...atteriet Koble positiv r d ladekabel til positiv p batteriet Koble negativ sort ladekabel til negativ p batteriet OVERBELASTNIGSVERN Overbelastningsvernet vil l se ut ved overbelastning av DC kursen d...

Page 7: ...avsl tt Ikke r yk eller bruk noen form for pen ild i n rheten av aggregatet n r fylling av bensin blir utf rt Det samme gjelder i omr der hvor bensin blir oppbevart Unng fylle for mye slik at det s l...

Page 8: ...Sett startbryteren i posisjon START 5 Slipp startbryteren med en gang aggregatet starter og la den g tilbake til utgangsposisjonen 6 Sett chokehendelen i posisjon PEN n r aggregatet motoren blir varm...

Page 9: ...cc hver 250 time Disse delene b r byttes om de begynner bli slitt Om eier ikke har n dvendig utstyr og kompetanse b r disse delene vedlikeholdes eller byttes av autorisert forhandler verksted NOTICE O...

Page 10: ...ren For forhindre problemer med forgasseren skal luftfilteret rengj res regelmessig Dette b r gj res oftere om aggregatet brukes i spesielt st vete og skitne omgivelser CAUTION Ikke bruk diesel bensin...

Page 11: ...p veivhuset for t mme aggregat for olje Sett p plass t mmepluggen fyll p motorolje til maksimalt niv og skru deretter peilepinnen p plass 3 Skru ut tennpluggen og t m ca en spiseskje med ren motorolj...

Page 12: ...0 kW Faktor 1 0 MOTOR Motor modell R500 V Motor type Luftkj lt 1 sylindret 4 takts OHV bensinmotor Sylindervolum 500 cc Drivstoff Bensin Tankkapasitet 028 liter Driftstid v kont belastning Ca 6 timer...

Page 13: ...13 Norsk...

Page 14: ...arnings in this manual and caution signs on the generator may not cover all hazardous circumstances If we do not give extra cautions for operating procedures methods or techniques operate the generato...

Page 15: ...ECIAL REQUIREMENTS Electrical equipment including lines and plug connections should be free from being bare The circuit breakers should match with the generator equipment If the circuit breakers requi...

Page 16: ...provide an enriched fuel mixture when starting a cold engine Slowly put the choke lever to OPEN position after the engine is started AC CIRCUIT BREAKER OVERCURRENT PROTECTOR The overload current will...

Page 17: ...n connecting the generator to a household power supply connection must be made by a qualified electrician After connecting carefully check electric connection for their safety and reliability if not d...

Page 18: ...load s positive to positive of DC terminal DC OVERCURRENT PROTECTOR The overload current will automatically switch off overcurrent protector to avoid short circuit of the load or overload If the indic...

Page 19: ...the engine stopped Never smoke or allow flames or sparks in the area where the engine is refueled or where gasoline is stored Do not overfill the fuel tank Avoid repeated or prolonged contact with ski...

Page 20: ...ticly return to open position 6 Turn the choke lever to OPEN position after the engine is warm NOTICE Turn the GENERATOR switch to electric position and hold for more than 5 seconds or damage may be c...

Page 21: ...ese items should be replaced if replacement needed These items should be maintained and repaired by our authorized dealer unless the owner has appropriate tools and is proficient with mechanical maint...

Page 22: ...malfunction service the air cleaner regularly Service more frequently when operating the generator in extremely dusty areas CAUTION Using gasoline or flammable solvent to clean the filter element can...

Page 23: ...gine stopped Never smoke or allow flames or sparks in the area during this procedure 2 Screw the oil dipstick off and screw the drain bolt off the crankcase to completely drain the oil out Then screw...

Page 24: ...wer 8 0 kW Factor 1 0 MOTOR Gasoline Engine Style R500 V Gasoline Engine Type Air cooled 4 storke OHV single cylinder Displacement 500 cc Fuel Bensin Fuel Volume 28 liter Continuing Time About 6 hours...

Page 25: ...25 English...

Page 26: ...26 English E...

Page 27: ...27 English...

Page 28: ...t er i samsvar med f lgende direktiver og standarder Intygar att denna produkt verensst mmer med kraven i f ljande direktiv och standarder Product Inverter generator Str maggregat Elverk Model Gebe 57...

Reviews: