15
English
- Should a maneuvering error due to the operator
occur.
- If the damage is attributable to insufficient routine
and/or extraordinary maintenance;
- If parts have been mounted on the Generator Set,
the use of which has not been authorized by Mega
Norge AS
- If the requirements regarding the use,
maintenance and assistance of the Generator Set,
con- tained in this Use and Maintenance Manual
and in the other manuals attached to the supply,
have not been respected.
Damages deriving from negligence, carelessness,
misuse and improper use of the machine are also
excluded from the warranty.
For repairs or overhauls of a certain complexity, it
is necessary to contact the authorized workshops or
directly Mega Norge AS , which is available to ensure
prompt and accurate technical assis- tance and
whatever is necessary to restore the full efficiency of
the Generator Set.
If the Parties do not intend to submit to arbitration
any disputes arising from the sup- ply contract or
in any other case in which the ruling of a judicial
body is required, only the Court of Verona will have
territorial jurisdiction.
This Manual contains some indications to warn the
reader about potential risks and dangers.
DANGER
DANGER: this is the signal at the highest level and
warns that, if the operations de- scribed are not
carried out correctly, they will cause serious injury,
death or long-term health risks.
WARNING
WARNING: this is a sign that warns that, if the above
operations are not carried out correctly, they can
cause serious injury, death or long-term health risks.
CAUTION
CAUTION: this is the signal that warns that, if the
above operations are not carried out correctly, they
can cause damage to the machine and/or to the
person.
This Manual is the basic tool for personnel who, in
various capacities, take care of the machine, such
as:
- Employees for the transport and handling of the
machine;
- Operators assigned to the various operations;
- Maintenance workers;
- Operators assigned to final demolition workers.
Before proceeding with the various operations, the
personnel listed above must have carefully read this
Manual.
1.3 DESCRIPTION AND IDENTIFICATION OF
THE GENERATOR SET
All the Generator Sets of the “G-THOR” range of
which Figure 1 is a typical example, are composed of
(refer to Figure 1):
1) Electrical cabinet
2) Alternator
3) Revolution multiplier
4) IP44 filters mounted on the alternator intake
and expulsion grilles (not supplied as standard,
they can be purchased as an accessory)
5) Protection bar kit (not supplied as standard, it
can be purchased as an accessory)
6) Suction IP 44 filter (not supplied as standard,
but available as an accessory)
7) Base with 3-point hitches (2 lower points and 1
upper point)
8) Upper third point hitch.
9) Cardan shaft protection hood.
10) Hitch with lower points.
11) Voltmeter.
12) Frequency meter (not supplied as standard, it
can be purchased as an accessory)
13) Hour counter (not supplied as standard, it can
be purchased as an accessory 14) Ammeter (not
supplied as standard, it can be purchased as an
accessory)
15) CEE 5-POLE full power three-phase power
socket
16) Single-phase 32A CEE 3-POLE power socket.
17) Single-phase 16A CEE 3POLE power socket.
18) Magnetothermic switch (which protects the
full power 32A CEE 5POLE three-phase current
socket).
19) Differential switch.
20) Bipolar magnetothermic switch (which protects
the single-phase 32A CEE 3 POLE power sock-
et).
21) Bipolar magnetothermic switch (which protects
the single-phase 16A CEE 3 POLE power sock-
et)
22) Screw to connect the ground
23) 4 wheels kit for handling in the yard (not
supplied as standard, but available as an
accessory)
Summary of Contents for 190103