– 25 –
Detergent/Rinse Module
The inner door panel on PermaTuf tub models and
the outer door panel on stainless steel tub models
must be removed to access the detergent/rinse
module. (See
Inner Door Panel (PermaTuf Tub Models)
or
Outer Door Panel (Stainless Steel Tub Models).
)
The detergent/rinse module is connected by 2 wires
and held in place by 6 Phillips-head screws and a
bracket.
The detergent/rinse module operates on 120 VAC
and has an approximate resistance value of 2 K
Bracket
The detergent/rinse mod ule au to mat i cal ly
dis pens es both de ter gent and rinse agent at the
ap pro pri ate times. The module is activated twice
during a wash cycle. Detergent is dispensed at the
beginning of the main wash cycle and rinse agent at
the beginning of the fi nal rinse.
Operation of the detergent/rinse module can be
checked by using the service test mode. (See
Service
Test Mode
.)
The fi rst time the module is activated, the lever
slides up the right-hand path of the connecting rod
(1). This action releases the de ter gent cover.
1
When deactivated, the lever returns down the left-
hand path and comes to rest under the notch (2) in
the center of the connecting rod.
At the second activation, the lever lifts the
con nect ing rod by the notch. This action lifts the
rinse dispenser plunger (3) and re leas es the rinse
agent. When deactivated, the lever returns to its
original start ing position.
2
3
Bottom Door Seal
The bottom door seal on PermaTuf tub models is
replaced by removing the inner door panel (See
Inner Door Panel (PermaTuf Tub Models)
.) Slide the
door seal to one side off the channel.
Door Seal
Note: When installing the door seal, be sure the seal
slides freely in the channel.
The bottom door seal on the stainless steel tub
models is riveted to the inner door panel. If the
bottom door seal needs to be replaced, replace the
inner door panel (See
Inner Door Panel (Stainless Steel
Tub Models).)